A Micro-phase Difference Measurement Circuit Using 4-bit Input Stage

This paper presents a transimpedance amplifier (TIA) used as a micro-phase difference measurement circuit for real-time monitoring of urine volume in the bladder. The proposed TIA consists of an input transconductance amplifiers (TCAs) and feedback TCAs. TIA requires adjustment of output amplitude when measuring micro-phase differences. The output amplitude is adjusted using the input transconductance of the input TCA. The transconductance of the input TCAs is adjusted using a 4-bit input stage whose transconductance can be changed by 4 -bit and the gate voltage $V_{\text {cont }}$ of a MOS connected in parallel with the 4-bit input stage. The power consumption of the proposed circuit is $910 \mu \mathrm{W}$ when supplied with a 5 V voltage and the circuit area is $0.182 \mathrm{mm}^{2}$. The results of measuring the micro phase difference with the proposed circuit showed an error rate of 0.160% for the same input signal amplitude and an error rate of 1.72% for a 1 mV difference in input voltage amplitude.

Authors

Institutions

Publication Details

Published
2024-11-07
DOI
https://doi.org/10.1109/apccas62602.2024.10808822
Citations
2
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Micro-phase Difference Measurement Circuit Using 4-bit Input Stage

Yuki Sasaki, Akio Shimizu, Yohei Ishikawa, Takuro Noguchi et al.
2 citations
Photonic and Optical Devices
0.42
article

A Micro-phase Difference Measurement Circuit Using 4-bit Input Stage

Yuki Sasaki, Akio Shimizu, Yohei Ishikawa, Takuro Noguchi, Sumio Fukai
article en
2 citations

Abstract

This paper presents a transimpedance amplifier (TIA) used as a micro-phase difference measurement circuit for real-time monitoring of urine volume in the bladder. The proposed TIA consists of an input transconductance amplifiers (TCAs) and feedback TCAs. TIA requires adjustment of output amplitude when measuring micro-phase differences. The output amplitude is adjusted using the input transconductance of the input TCA. The transconductance of the input TCAs is adjusted using a 4-bit input stage whose transconductance can be changed by 4 -bit and the gate voltage $V_{\text {cont }}$ of a MOS connected in parallel with the 4-bit input stage. The power consumption of the proposed circuit is $910 \mu \mathrm{W}$ when supplied with a 5 V voltage and the circuit area is $0.182 \mathrm{mm}^{2}$. The results of measuring the micro phase difference with the proposed circuit showed an error rate of 0.160% for the same input signal amplitude and an error rate of 1.72% for a 1 mV difference in input voltage amplitude.

Saga University (JP), National Institute of Technology, Ariake College (JP)
Synopsys
Affordable and clean energy
Openalex Percentile: Top 36%
Photonic and Optical Devices
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.