Bilateral comparison of gas microflow primary standards in the range between 0.12 mg/min and 2.4 mg/min

A bilateral comparison of small gas flow rates in the range between 0.12 mg/min and 2.4 mg/min was performed between INRiM (Italy) and LMPS (Slovenia). The primary standard at INRiM is a type of a motor driven piston prover. The primary standard at LMPS is a pVTt method with a static mass determination and flying start-stop. The transfer standard main part are two capillary leaks, with measuring ranges up to 0.25 mg/min and 2.5 mg/min respectively. A Hagen-Poiseuille equation with a constant geometric factor is used to calculate the mass flow rate. The comparison was carried out at five measurement points with the large capillary leak and at two points with the small capillary leak. The results show that there are statistically significant differences between the measurements of the two laboratories. The estimated uncertainties are also too large to confirm the target CMCs, as the repeatability of the measurements was too weak.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-27
DOI
https://doi.org/10.1016/j.measen.2024.101588
Primary Topic
Intravenous Infusion Technology and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bilateral comparison of gas microflow primary standards in the range between 0.12 mg/min and 2.4 mg/min

Pier Giorgio Spazzini, G. Bobovnik, Primož Žibret, Jože Kutin
3 links
Measurement Sensors
Intravenous Infusion Technology and Safety
article

Bilateral comparison of gas microflow primary standards in the range between 0.12 mg/min and 2.4 mg/min

Pier Giorgio Spazzini, G. Bobovnik, Primož Žibret, Jože Kutin
article en

Abstract

A bilateral comparison of small gas flow rates in the range between 0.12 mg/min and 2.4 mg/min was performed between INRiM (Italy) and LMPS (Slovenia). The primary standard at INRiM is a type of a motor driven piston prover. The primary standard at LMPS is a pVTt method with a static mass determination and flying start-stop. The transfer standard main part are two capillary leaks, with measuring ranges up to 0.25 mg/min and 2.5 mg/min respectively. A Hagen-Poiseuille equation with a constant geometric factor is used to calculate the mass flow rate. The comparison was carried out at five measurement points with the large capillary leak and at two points with the small capillary leak. The results show that there are statistically significant differences between the measurements of the two laboratories. The estimated uncertainties are also too large to confirm the target CMCs, as the repeatability of the measurements was too weak.

Measurement SensorsVol. 38
University of Ljubljana (SI), Istituto Nazionale di Ricerca Metrologica (IT)
Openalex Percentile: Top 77%
Intravenous Infusion Technology and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.