Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation

Substances leached from a medical device during its clinical use are important due to the patient health-related effects they may have. Thus, medical devices are profiled for leachables (and/or extractables as probable leachables) by screening extracts or leachates of the medical device for released organic substances via a non-target analysis (NTA) employing chromatographic methods coupled with mass spectrometric detection. Chromatographic mass spectral response factors for extractables and leachables vary significantly from compound to compound, complicating the application of assessment strategies such as the analytical evaluation threshold (AET), which is the concentration threshold at or above which an extractable or leachable must be reported for quantitative toxicological risk assessment. The analytical uncertainty resulting from response variation can make interpretation of the AET difficult, potentially leading to both false positive and false negative outcomes. Furthermore, response factor variation complicates the estimation of leachables' and extractables' concentrations (quantification). This Correspondence discusses practices for the calculation and application of the AET and for performing quantification, including a discussion of accuracy versus protectiveness.

Authors

Institutions

Publication Details

Journal
PDA Journal of Pharmaceutical Science and Technology
Published
2024-12-27
DOI
https://doi.org/10.5731/pdajpst.2024.012945
Citations
1
Primary Topic
Animal testing and alternatives
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation

Dennis Jenke, Piet Christiaens, Ted Heise
1 citations
PDA Journal of Pharmaceutical Science and Technology
Animal testing and alternatives
0.64
article

Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation

Dennis Jenke, Piet Christiaens, Ted Heise
article en
1 citations

Abstract

Substances leached from a medical device during its clinical use are important due to the patient health-related effects they may have. Thus, medical devices are profiled for leachables (and/or extractables as probable leachables) by screening extracts or leachates of the medical device for released organic substances via a non-target analysis (NTA) employing chromatographic methods coupled with mass spectrometric detection. Chromatographic mass spectral response factors for extractables and leachables vary significantly from compound to compound, complicating the application of assessment strategies such as the analytical evaluation threshold (AET), which is the concentration threshold at or above which an extractable or leachable must be reported for quantitative toxicological risk assessment. The analytical uncertainty resulting from response variation can make interpretation of the AET difficult, potentially leading to both false positive and false negative outcomes. Furthermore, response factor variation complicates the estimation of leachables' and extractables' concentrations (quantification). This Correspondence discusses practices for the calculation and application of the AET and for performing quantification, including a discussion of accuracy versus protectiveness.

PDA Journal of Pharmaceutical Science and TechnologyVol. 79(1)
Scientific Solutions (United States) (US), Research & Development Institute (US), Triad National Security (United States) (US)
Zero hunger
Openalex Percentile: Top 25%
Animal testing and alternatives
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation — Dennis Jenke, Piet Christiaens, et al. · PDA Journal of Pharmaceutical Science and Technology (2024) | TGRS Research Map | TGRS