Nitrogen vacancy centers integrated magnetometer based on multi-frequency modulation measurement technique

Purpose This study aims to improve the sensitivity of magnetic detection. In this article, a multi-frequency modulation technique is used to increase the magnetic detection sensitivity of diamond nitrogen vacancy (NV) centers sensors. Design/methodology/approach In the field of magnetic detection, NV centers have corresponding advantages due to their unique long coherence property at room temperature. The important indicators for NV centers magnetometers are the magnetic detection sensitivity of the NV centers and the integration of the magnetometer. To solve this problem, the authors propose a multi-frequency modulated magnetic detection technique, using an integrated probe as well as a lock-in amplifier for the double enhancement of sensitivity as well as integration. Findings The following results can be obtained by processing and calculating the experimental data with an integrated lock-in amplifier circuit with an area of 27.50 cm 2 and a probe volume of 3.12 cm 3 . The multi-frequency modulation technique was used to increase the magnetic detection sensitivity of the NV centers from 8.59 nT/Hz1 / 2–2.42 nT/Hz1 / 2. Research limitations/implications The authors propose a signal modulation technique with an integrated design, which achieves an improvement in the sensitivity of the sensor’s magnetic detection through practical testing. Originality/value The authors propose a signal modulation technique with an integrated design, which achieves an improvement in the sensitivity of the sensor’s magnetic detection through practical testing. This technique provides new research solution for the subsequent improvement of the magnetic detection sensitivity.

Authors

Institutions

Publication Details

Journal
Sensor Review
Published
2024-12-27
DOI
https://doi.org/10.1108/sr-10-2024-0839
Citations
1
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nitrogen vacancy centers integrated magnetometer based on multi-frequency modulation measurement technique

Guihao Ran, С Ран, Xiaobiao Mao, Tao Hu et al.
1 citations
Sensor Review
Diamond and Carbon-based Materials Research
0.12
article

Nitrogen vacancy centers integrated magnetometer based on multi-frequency modulation measurement technique

Guihao Ran, С Ран, Xiaobiao Mao, Tao Hu, Xinhui He, Kun Huang, Zhennan Lin, Qin Hu
article en
1 citations

Abstract

Purpose This study aims to improve the sensitivity of magnetic detection. In this article, a multi-frequency modulation technique is used to increase the magnetic detection sensitivity of diamond nitrogen vacancy (NV) centers sensors. Design/methodology/approach In the field of magnetic detection, NV centers have corresponding advantages due to their unique long coherence property at room temperature. The important indicators for NV centers magnetometers are the magnetic detection sensitivity of the NV centers and the integration of the magnetometer. To solve this problem, the authors propose a multi-frequency modulated magnetic detection technique, using an integrated probe as well as a lock-in amplifier for the double enhancement of sensitivity as well as integration. Findings The following results can be obtained by processing and calculating the experimental data with an integrated lock-in amplifier circuit with an area of 27.50 cm 2 and a probe volume of 3.12 cm 3 . The multi-frequency modulation technique was used to increase the magnetic detection sensitivity of the NV centers from 8.59 nT/Hz1 / 2–2.42 nT/Hz1 / 2. Research limitations/implications The authors propose a signal modulation technique with an integrated design, which achieves an improvement in the sensitivity of the sensor’s magnetic detection through practical testing. Originality/value The authors propose a signal modulation technique with an integrated design, which achieves an improvement in the sensitivity of the sensor’s magnetic detection through practical testing. This technique provides new research solution for the subsequent improvement of the magnetic detection sensitivity.

Sensor ReviewVol. 45(2)
North University of China (CN)
Openalex Percentile: Top 57%
Diamond and Carbon-based Materials Research
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.