Dual-biased metal oxide electrolyte-gated thin-film transistors for enhanced protonation in complex biofluids
pH sensing technology is pivotal for monitoring aquatic ecosystems and diagnosing human health conditions. Indium-gallium-zinc oxide electrolyte-gated thin-film transistors (IGZO EGTFTs) are highly regarded as ion-sensing devices due to the pH-dependent surface chemistry of their sensing membranes. However, applying EGTFT-based pH sensors in complex biofluids containing diverse charged species poses challenges due to ion interference and inherently low sensitivity constrained by the Nernst limit. Here, we propose a dual-biased (DB) EGTFT pH sensing platform, acquiring back-gate-assisted sensitivity enhancement and recyclable redox-coupled protonation at the semiconductor-biofluid interface. A solution-processed amorphous IGZO film, used as the proton-sensitive membrane, ensures scalable uniformity across a 6-inch wafer. These devices demonstrate exceptional pH resistivity over several hours when submerged in solutions with pH levels of 4 and 8. In-depth electrochemical investigations reveal that back-gate bias significantly enhances sensitivity beyond the Nernst limit, reaching 85 mV/pH. This improvement is due to additional charge accumulation in the channel, which expands the sensing window. As a proof of concept, we observe consistent variations in threshold voltage during repeated pH cycles, not only in standard solutions but also in physiological electrolytes such as phosphate-buffered saline (PBS) and artificial urine, confirming the potential for reliable operation in complex biological environments.
Authors
- Jun‐Gyu Choi (ORCID: https://orcid.org/0000-0001-7501-3242)
- Yoonseok Song
- Chuljin Hwang (ORCID: https://orcid.org/0000-0001-5646-2077)
- Seokhyeon Baek (ORCID: https://orcid.org/0009-0006-1239-546X)
- Sungjun Park (ORCID: https://orcid.org/0000-0001-9603-902X)
Institutions
- Ajou University (KR)
Publication Details
- Journal
- Scientific Reports
- Published
- 2024-12-28
- DOI
- https://doi.org/10.1038/s41598-024-80005-0
- Citations
- 3
- Primary Topic
- Analytical Chemistry and Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.87
Funders
- National Research Foundation
- Ministry of Trade, Industry and Energy
- Korea Institute for Advancement of Technology
- Korea Basic Science Institute
- National Research Foundation of Korea
- Ministry of Education, India
- Iran Telecommunication Research Center
- Ministry of Science and ICT, South Korea
- Commercializations Promotion Agency for R and D Outcomes
- Institute for Information and Communications Technology Promotion