Experimental investigation on thermal performance of gravity heat pipe with different pipe configurations

Gravity heat pipe (GHP) is a critical heat transfer device for enhancing heat transfer efficiency in many fields. The heat transfer performance of GHP is significantly influenced by its pipe configuration. The present study aims at elucidating the impact of pipe configuration on the thermal performance of GHP through experiments. The typical pipe configuration, including conventional vertical inserted straight pipe, oblique inserted straight pipe and curved pipe, were tested and analyzed under equivalent pipe area and equivalent vertical pipe height. It was found that the curved GHPs with equivalent vertical pipe height was the best configuration with optimal curving angle. Following this, a parameter sensitivity analysis using the response surface method was conducted for the curved GHP to further improving its thermal performance. This analysis examined the heat transfer performance of the curved GHP with varied main factors, including evaporator input power (40W, 60W, 80W), filling ratio (20 %, 30 %, 40 %) and curving angle (30°, 45°, 60°). Mathematical correlations are derived for the heat transfer coefficient, thermal resistance, and equivalent thermal conductivity for the curved GHP. The results indicate that the sensitivity ranking for thermal performance of the curved GHP is: input power > filling ratio > curving angle.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-12-27
DOI
https://doi.org/10.1016/j.csite.2024.105695
Citations
13
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
2.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on thermal performance of gravity heat pipe with different pipe configurations

Renkun Dai, Xulei Tong, Yang Xiao, Xing Lu et al.
13 citations
Case Studies in Thermal Engineering
Heat Transfer and Boiling Studies
2.76
article

Experimental investigation on thermal performance of gravity heat pipe with different pipe configurations

Renkun Dai, Xulei Tong, Yang Xiao, Xing Lu, Jie Liu, Jun Deng
article en
13 citations

Abstract

Gravity heat pipe (GHP) is a critical heat transfer device for enhancing heat transfer efficiency in many fields. The heat transfer performance of GHP is significantly influenced by its pipe configuration. The present study aims at elucidating the impact of pipe configuration on the thermal performance of GHP through experiments. The typical pipe configuration, including conventional vertical inserted straight pipe, oblique inserted straight pipe and curved pipe, were tested and analyzed under equivalent pipe area and equivalent vertical pipe height. It was found that the curved GHPs with equivalent vertical pipe height was the best configuration with optimal curving angle. Following this, a parameter sensitivity analysis using the response surface method was conducted for the curved GHP to further improving its thermal performance. This analysis examined the heat transfer performance of the curved GHP with varied main factors, including evaporator input power (40W, 60W, 80W), filling ratio (20 %, 30 %, 40 %) and curving angle (30°, 45°, 60°). Mathematical correlations are derived for the heat transfer coefficient, thermal resistance, and equivalent thermal conductivity for the curved GHP. The results indicate that the sensitivity ranking for thermal performance of the curved GHP is: input power > filling ratio > curving angle.

Case Studies in Thermal EngineeringVol. 65
Xi'an University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 9%
Heat Transfer and Boiling Studies
2.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.