Data-driven and model-guided iterative reconstruction framework for simultaneous sparse-view and ring artifact reduction in synchrotron X-ray microtomography

Synchrotron X-ray microtomography (S-µCT) is a highly valuable technique for investigating organ function and pathologies. However, its application is often limited by high radiation doses and the occurrence of ring artifacts. While S-µCT utilizing sparse-view projections can effectively decrease radiation doses, the reconstructed images frequently exhibit severe streaking artifacts, which are exacerbated by ring artifacts, ultimately compromising reconstruction accuracy, image quality, and resolution. Previous research has primarily focused on either sparse-view CT reconstruction or ring artifact reduction, leaving the issue of simultaneous sparse-view and ring artifact reduction under-explored. In this study, we propose a data-driven and model-guided iterative reconstruction framework for S-µCT to address this issue. Specifically, this framework integrates a data prior derived from a score-based generative model to tackle the streaking artifacts introduced by sparse-view projections, along with a model prior obtained from a regularization model to suppress ring artifacts. To assess the effectiveness and capabilities of the proposed framework, simulations using foam phantoms and real S-µCT experiments involving rat liver samples were conducted. The results demonstrated that the proposed framework effectively reduces both streaking and ring artifacts, yielding high-quality S-µCT images with significant reconstruction accuracy and improved image resolution. These findings suggest that the proposed framework holds considerable promise for expanding the application of S-µCT in the future.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-12-27
DOI
https://doi.org/10.1364/oe.549522
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-driven and model-guided iterative reconstruction framework for simultaneous sparse-view and ring artifact reduction in synchrotron X-ray microtomography

Xinyan Zhao, Dongjiang Ji, Jianbo Jian, Chunhong Hu et al.
1 citations
Optics Express
Medical Imaging Techniques and Applications
0.40
article

Data-driven and model-guided iterative reconstruction framework for simultaneous sparse-view and ring artifact reduction in synchrotron X-ray microtomography

Xinyan Zhao, Dongjiang Ji, Jianbo Jian, Chunhong Hu, Yimin Li, Yi He, Wenjuan Lv, Fangzhi Li, Chenyang Ma, Yuqing Zhao, Ziyao Wang
article en
1 citations

Abstract

Synchrotron X-ray microtomography (S-µCT) is a highly valuable technique for investigating organ function and pathologies. However, its application is often limited by high radiation doses and the occurrence of ring artifacts. While S-µCT utilizing sparse-view projections can effectively decrease radiation doses, the reconstructed images frequently exhibit severe streaking artifacts, which are exacerbated by ring artifacts, ultimately compromising reconstruction accuracy, image quality, and resolution. Previous research has primarily focused on either sparse-view CT reconstruction or ring artifact reduction, leaving the issue of simultaneous sparse-view and ring artifact reduction under-explored. In this study, we propose a data-driven and model-guided iterative reconstruction framework for S-µCT to address this issue. Specifically, this framework integrates a data prior derived from a score-based generative model to tackle the streaking artifacts introduced by sparse-view projections, along with a model prior obtained from a regularization model to suppress ring artifacts. To assess the effectiveness and capabilities of the proposed framework, simulations using foam phantoms and real S-µCT experiments involving rat liver samples were conducted. The results demonstrated that the proposed framework effectively reduces both streaking and ring artifacts, yielding high-quality S-µCT images with significant reconstruction accuracy and improved image resolution. These findings suggest that the proposed framework holds considerable promise for expanding the application of S-µCT in the future.

Optics ExpressVol. 33(2)
Tianjin University of Technology and Education (CN), Capital University (US), Capital Medical University (CN), Tianjin Medical University General Hospital (CN), National Clinical Research Center for Digestive Diseases (CN)
National Natural Science Foundation of China, Tianjin Municipal Education Commission
Sustainable cities and communities
Openalex Percentile: Top 31%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.