Engineering an Ionic Aggregation-Induced Luminescence-Labeled Fluorescence Lateral Flow Immunoassay for C-Reactive Protein in Human Plasma

The surge of lateral flow immunoassays (LFAs) stimulates researchers to explore the novel vibrant aggregation-induced emission luminogen (AIEgen)-doped nanoparticles to improve the accuracy and reliability of LFAs. However, the loading amount of AIEgens currently used for the LFA in microspheres is limited due to their symmetrical large conjugated skeleton structure, which significantly reduces the fluorescence brightness of the signal reporter in the LFA. Herein, an ionic AIEgens with a donor-acceptor type was developed as the signal reporter of the LFA for C-reactive protein (CRP). Ionic AIEgens are unable to enter the hydrophobic cavity of polystyrene nanoparticles (PS) because of their low hydrophobic nature. By altering ionic AIEgens with extended alkyl chains, it is possible to increase their hydrophobicity, thereby potentially increasing the loading capacity within PS. Notably, the fluorescent nanoparticles (denoted as AIE<sub>TPA</sub>NPs) formed by embedding (<i>E</i>)-4-(4-(diphenylamino)styryl)-1-octadecylpyridin-1-ium iodide (TPA) in PS showed orange-red fluorescence emission and have high fluorescence quantum yield. Anti-CRP antibody (mAb1) could be effectively conjugated to the surface of AIE<sub>TPA</sub>NPs by an amino-carboxyl reaction, resulting in AIE<sub>TPA</sub>NPs-mAb1. The AIE<sub>TPA</sub>NPs-mAb1 exhibited a fluorescence emission at 613 nm, a point detectable by the naked eye with minimal background interference. The entire analysis was accomplished in just 10 min, achieving a limit of detection of 4.06 ng/mL for CRP. The AIE<sub>TPA</sub>NPs-mAb1-based LFA demonstrates excellent stability and specificity and fully meets the requirements for clinical diagnosis.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-12-27
DOI
https://doi.org/10.1021/acs.analchem.4c04803
Citations
8
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
1.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Engineering an Ionic Aggregation-Induced Luminescence-Labeled Fluorescence Lateral Flow Immunoassay for C-Reactive Protein in Human Plasma

Baodui Wang, Ning Gao, Pei-Yuan Sun, Q. Li et al.
8 citations
Analytical Chemistry
Biosensors and Analytical Detection
1.48
article

Engineering an Ionic Aggregation-Induced Luminescence-Labeled Fluorescence Lateral Flow Immunoassay for C-Reactive Protein in Human Plasma

Baodui Wang, Ning Gao, Pei-Yuan Sun, Q. Li, Wei-Tun Chang, Zhonghua Xue, M. X. Luo, Haile Liu
article en
8 citations

Abstract

The surge of lateral flow immunoassays (LFAs) stimulates researchers to explore the novel vibrant aggregation-induced emission luminogen (AIEgen)-doped nanoparticles to improve the accuracy and reliability of LFAs. However, the loading amount of AIEgens currently used for the LFA in microspheres is limited due to their symmetrical large conjugated skeleton structure, which significantly reduces the fluorescence brightness of the signal reporter in the LFA. Herein, an ionic AIEgens with a donor-acceptor type was developed as the signal reporter of the LFA for C-reactive protein (CRP). Ionic AIEgens are unable to enter the hydrophobic cavity of polystyrene nanoparticles (PS) because of their low hydrophobic nature. By altering ionic AIEgens with extended alkyl chains, it is possible to increase their hydrophobicity, thereby potentially increasing the loading capacity within PS. Notably, the fluorescent nanoparticles (denoted as AIE<sub>TPA</sub>NPs) formed by embedding (<i>E</i>)-4-(4-(diphenylamino)styryl)-1-octadecylpyridin-1-ium iodide (TPA) in PS showed orange-red fluorescence emission and have high fluorescence quantum yield. Anti-CRP antibody (mAb1) could be effectively conjugated to the surface of AIE<sub>TPA</sub>NPs by an amino-carboxyl reaction, resulting in AIE<sub>TPA</sub>NPs-mAb1. The AIE<sub>TPA</sub>NPs-mAb1 exhibited a fluorescence emission at 613 nm, a point detectable by the naked eye with minimal background interference. The entire analysis was accomplished in just 10 min, achieving a limit of detection of 4.06 ng/mL for CRP. The AIE<sub>TPA</sub>NPs-mAb1-based LFA demonstrates excellent stability and specificity and fully meets the requirements for clinical diagnosis.

Analytical ChemistryVol. 97(1)
BioElectronics (United States) (US), State Key Laboratory of Applied Organic Chemistry, Northwest Normal University (CN), Lanzhou University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Gansu Province
Openalex Percentile: Top 18%
Biosensors and Analytical Detection
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.