The influence of zonal air supply on thermal comfort in a classroom located in a hot and humid environment: a case study from Jeddah—Saudi Arabia

Abstract In hot and humid regions, many classrooms depend on air conditioning systems equipped with mixing ventilation to maintain acceptable indoor temperatures. However, this method often proves inadequate in delivering satisfactory thermal comfort due to elevated temperature and poor air distribution. This research explores the potential of zonal air supply strategies to enhance thermal comfort in a classroom situated in Jeddah, Saudi Arabia. During July 2024, field data—including measurements of airflow velocity, air temperature, relative humidity, and globe temperature—were collected to find key thermal comfort indices: Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD). In addition, a survey was administered to assess students’ thermal perceptions. Computational Fluid Dynamics (CFD) simulations were utilized to predict air temperature, velocity, and humidity distribution, evaluating the impact of zonal air supply designs on thermal comfort within the classroom. Parametric analysis was used to identify the most effective zonal air supply configuration for reducing PMV and PPD values. The findings show that, under existing ventilation conditions, PMV and PPD indices at different heights exceed the recommended limits established by ASHRAE Standard-55, indicating thermal discomfort during peak temperature periods. Further investigation demonstrated that introducing a 4-zonal air supply system could reduce PMV by 16–32% and PPD by 32–36%, thereby significantly improving thermal comfort in the classroom.

Authors

Institutions

Publication Details

Journal
Discover Sustainability
Published
2024-12-27
DOI
https://doi.org/10.1007/s43621-024-00769-3
Citations
5
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The influence of zonal air supply on thermal comfort in a classroom located in a hot and humid environment: a case study from Jeddah—Saudi Arabia

Haslinda Mohamed Kamar, Fuad A. Ghaleb, Zuhair Jastaneyah, Hakim AL Garalleh et al.
5 citations
Discover Sustainability
Building Energy and Comfort Optimization
1.33
article

The influence of zonal air supply on thermal comfort in a classroom located in a hot and humid environment: a case study from Jeddah—Saudi Arabia

Haslinda Mohamed Kamar, Fuad A. Ghaleb, Zuhair Jastaneyah, Hakim AL Garalleh, Ahmad Hashmi
article en
5 citations

Abstract

Abstract In hot and humid regions, many classrooms depend on air conditioning systems equipped with mixing ventilation to maintain acceptable indoor temperatures. However, this method often proves inadequate in delivering satisfactory thermal comfort due to elevated temperature and poor air distribution. This research explores the potential of zonal air supply strategies to enhance thermal comfort in a classroom situated in Jeddah, Saudi Arabia. During July 2024, field data—including measurements of airflow velocity, air temperature, relative humidity, and globe temperature—were collected to find key thermal comfort indices: Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD). In addition, a survey was administered to assess students’ thermal perceptions. Computational Fluid Dynamics (CFD) simulations were utilized to predict air temperature, velocity, and humidity distribution, evaluating the impact of zonal air supply designs on thermal comfort within the classroom. Parametric analysis was used to identify the most effective zonal air supply configuration for reducing PMV and PPD values. The findings show that, under existing ventilation conditions, PMV and PPD indices at different heights exceed the recommended limits established by ASHRAE Standard-55, indicating thermal discomfort during peak temperature periods. Further investigation demonstrated that introducing a 4-zonal air supply system could reduce PMV by 16–32% and PPD by 32–36%, thereby significantly improving thermal comfort in the classroom.

Discover SustainabilityVol. 5(1)
University of Business and Technology (SA), University of Technology Malaysia (MY)
Openalex Percentile: Top 20%
Building Energy and Comfort Optimization
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.