Patient Positional Uncertainty and Margin Reduction in Lung Stereotactic Ablative Radiation Therapy Using Pneumatic Abdominal Compression
Clinical data suggest that the uniform 5.0-mm margin is conservative for our workflow. Using modern techniques such as 4D CT, 4D CBCT, and effective motion management can significantly reduce required margins, and therefore necessary healthy tissue dose. However, the limitations of margin calculation models must be considered, and margin reduction must be approached with caution. Users should conduct a formal risk assessment prior to adopting new standard PTV margins.
Authors
- James C Henry
- Bethany L. Broekhoven
- Yohan Walter (ORCID: https://orcid.org/0000-0003-3758-9093)
- Chiachien J. Wang
- Anne M. Hubbard (ORCID: https://orcid.org/0000-0003-0998-8679)
- Joseph P. Dugas
- Daniel B. Speir
- Hsinshun Terry Wu
- Troy D. Jacobs
- M. Rodrigues
- William E. Burrell
- Philip F Durham
- Carlos D Palomeque
Institutions
- Willis-Knighton Cancer Center (US)
Publication Details
- Journal
- Practical Radiation Oncology
- Published
- 2024-12-27
- DOI
- https://doi.org/10.1016/j.prro.2024.12.001
- Citations
- 6
- Primary Topic
- Lung Cancer Diagnosis and Treatment
- Type
- article
- Field-Weighted Citation Impact
- 2.51