A geometrical optimisation of a coplanar micro-electrode structure for microfluidic flow cytometry

Single-cell analysis provides a more information-rich approach to disease diagnosis than traditional methods.At the cellular level, electrical properties have been established as reliable disease markers, capable of revealing variations between individual cells.This study focuses on optimising the geometry of a coplanar micro-electrode structure for detecting human lung adenocarcinoma cells (A549) within a fluid channel using impedance flow cytometry.A549 cells were chosen due to their frequent occurrence in cancer cases and the extensive documentation of their electrical properties and size.To further investigate the electric field and optimise the electrode design for single-cell detection, a numerical 3D model based on the finite element method (FEM) was developed and implemented.The functionality of the sensing structure was validated using COMSOL Multiphysics, with the Electric Current module defining scalar electric potential within the 3D model.Simulations explored various parameters, including electrode dimensions, frequency range, object sizes, and electrical conductivity, to fine-tune the sensor's performance.Additionally, the study elucidates the impact of cell position within the channel structure and cell size on impedance measurements.This numerical investigation provides insights into the acquired impedance signals, contributing to the optimisation and standardisation of the device.The proposed sensor system holds significant potential across various applications in biomedicine and chemistry, particularly in point-of-care scenarios, where the sensor chip can be conveniently configured for measurements and discarded after use.

Authors

Institutions

Publication Details

Journal
Ministry of Science and Technology Vietnam
Published
2024-12-15
DOI
https://doi.org/10.31276/vjste.2024.0014
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A geometrical optimisation of a coplanar micro-electrode structure for microfluidic flow cytometry

Thu Hang Nguyen, Quang Loc, Van Phu Nguyen, Trung Kien et al.
Ministry of Science and Technology Vietnam
Microfluidic and Bio-sensing Technologies
article

A geometrical optimisation of a coplanar micro-electrode structure for microfluidic flow cytometry

Thu Hang Nguyen, Quang Loc, Van Phu Nguyen, Trung Kien, Trung-Hieu Dang, Van Thanh Pham, Van-Anh Bui
article en

Abstract

Single-cell analysis provides a more information-rich approach to disease diagnosis than traditional methods.At the cellular level, electrical properties have been established as reliable disease markers, capable of revealing variations between individual cells.This study focuses on optimising the geometry of a coplanar micro-electrode structure for detecting human lung adenocarcinoma cells (A549) within a fluid channel using impedance flow cytometry.A549 cells were chosen due to their frequent occurrence in cancer cases and the extensive documentation of their electrical properties and size.To further investigate the electric field and optimise the electrode design for single-cell detection, a numerical 3D model based on the finite element method (FEM) was developed and implemented.The functionality of the sensing structure was validated using COMSOL Multiphysics, with the Electric Current module defining scalar electric potential within the 3D model.Simulations explored various parameters, including electrode dimensions, frequency range, object sizes, and electrical conductivity, to fine-tune the sensor's performance.Additionally, the study elucidates the impact of cell position within the channel structure and cell size on impedance measurements.This numerical investigation provides insights into the acquired impedance signals, contributing to the optimisation and standardisation of the device.The proposed sensor system holds significant potential across various applications in biomedicine and chemistry, particularly in point-of-care scenarios, where the sensor chip can be conveniently configured for measurements and discarded after use.

Ministry of Science and Technology VietnamVol. 66(4)
Vietnam National University, Hanoi (VN)
Openalex Percentile: Top 77%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A geometrical optimisation of a coplanar micro-electrode structure for microfluidic flow cytometry — Thu Hang Nguyen, Quang Loc, et al. · Ministry of Science and Technology Vietnam (2024) | TGRS Research Map | TGRS