Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices

Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising <i>N</i>-isopropylacrylamide (NIPAM), <i>N</i>,<i>N</i>'-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L<sup>-1</sup>). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-12-25
DOI
https://doi.org/10.1021/acs.analchem.4c05363
Citations
6
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices

Chung-Lun Kuo, Cheng‐Kuan Su
6 citations
Analytical Chemistry
Microfluidic and Capillary Electrophoresis Applications
1.11
article

Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices

Chung-Lun Kuo, Cheng‐Kuan Su
article en
6 citations

Abstract

Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising <i>N</i>-isopropylacrylamide (NIPAM), <i>N</i>,<i>N</i>'-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L<sup>-1</sup>). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.

Analytical ChemistryVol. 97(2)
National Chung Hsing University (TW), National Taipei University (TW)
National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 24%
Microfluidic and Capillary Electrophoresis Applications
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.