Assessment of Noise Pollution Level of Selected Construction Sites with in the Residential Area in Obio/Akpo Local Government Area, Rivers States, Nigeria

The measurement of industrial noise pollution level of selected construction sites within residential area in Obio/Akpo Local Government Area of Rivers State has been carried out. The noise level meter with range of 30.0 - 80.0 dBA. (BK Precision 732, IEC 651 TYPE II) was use in measuring the sound level of the selected construction sites. Four (4) selected construction sites was considered for the measurement of industrial noise pollution of the construction sites. The obtained results of the selected construction sites vary from 77.40 - 81.25 dBA, 77.0 - 80.90 dBA, 75.4 - 81.15 dBA, 67.30 – 81.90 dBA with mean of 79.77 dBA, 77.41 dBA,79.53 dBA, 70.21 dBA for Plus Steel, Zortex, Darlington and Gift Construction Site respectively. Higher noise pollution level was obtained from Pius Steel Construction site with mean of 79.77 dBA and the least noise level was recorded at Gift Construction Site with mean value of 70.21 dBA. The obtained results of the selected construction sites were higher than the stipulated value of 65.0 dBA and 55.0 dBA decibels for industrial and residential area recommended by NESREA (2009). The noise percentage of the construction sites is of the increasing order of Gift, Pius < Zortex < Darlington < Pius Steel Construction Sites and the least percentage was obtained in Gift construction site while the higher noise percentage was recorded in Pius Steel Construction site with 27% increment. The obtained noise pollution level of the selected construction sites within the study area shows that the workers and the residential area are exposed to high noise level. The obtained result may not pose any immediate health risk but an individual who may spent his/her life time within the area, may develop hearing impairment in the nearer time due to over exposure to noise pollution level within the immediate environment and construction sites should be located outside the residential area.

Authors

Institutions

Publication Details

Journal
Asian Journal of Advanced Research and Reports
Published
2024-12-26
DOI
https://doi.org/10.9734/ajarr/2024/v18i12848
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Noise Pollution Level of Selected Construction Sites with in the Residential Area in Obio/Akpo Local Government Area, Rivers States, Nigeria

Noah Abel, Biibaloo L. Legborsi, Nwanne T. Ilugo
Asian Journal of Advanced Research and Reports
Noise Effects and Management
article

Assessment of Noise Pollution Level of Selected Construction Sites with in the Residential Area in Obio/Akpo Local Government Area, Rivers States, Nigeria

Noah Abel, Biibaloo L. Legborsi, Nwanne T. Ilugo
article en

Abstract

The measurement of industrial noise pollution level of selected construction sites within residential area in Obio/Akpo Local Government Area of Rivers State has been carried out. The noise level meter with range of 30.0 - 80.0 dBA. (BK Precision 732, IEC 651 TYPE II) was use in measuring the sound level of the selected construction sites. Four (4) selected construction sites was considered for the measurement of industrial noise pollution of the construction sites. The obtained results of the selected construction sites vary from 77.40 - 81.25 dBA, 77.0 - 80.90 dBA, 75.4 - 81.15 dBA, 67.30 – 81.90 dBA with mean of 79.77 dBA, 77.41 dBA,79.53 dBA, 70.21 dBA for Plus Steel, Zortex, Darlington and Gift Construction Site respectively. Higher noise pollution level was obtained from Pius Steel Construction site with mean of 79.77 dBA and the least noise level was recorded at Gift Construction Site with mean value of 70.21 dBA. The obtained results of the selected construction sites were higher than the stipulated value of 65.0 dBA and 55.0 dBA decibels for industrial and residential area recommended by NESREA (2009). The noise percentage of the construction sites is of the increasing order of Gift, Pius < Zortex < Darlington < Pius Steel Construction Sites and the least percentage was obtained in Gift construction site while the higher noise percentage was recorded in Pius Steel Construction site with 27% increment. The obtained noise pollution level of the selected construction sites within the study area shows that the workers and the residential area are exposed to high noise level. The obtained result may not pose any immediate health risk but an individual who may spent his/her life time within the area, may develop hearing impairment in the nearer time due to over exposure to noise pollution level within the immediate environment and construction sites should be located outside the residential area.

Asian Journal of Advanced Research and ReportsVol. 18(12)
University of Port Harcourt (NG)
Sustainable cities and communities
Openalex Percentile: Top 62%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.