Technical condition assessment of a small-sized nuclear power plant after transportation unit overturning

The article considers the final stage of emergency development associated with the transport unit overturning with a small-sized nuclear power plant. Mathematical modelling allowed to obtain information about possible consequences. Among the most serious foreseeable damages are violations of the thermal protection coating in the area of the tip and bottom of the unit, which is a part of the separating head unit. To assess the unacceptability of this or that damage, the method of calculation of aerodynamic characteristics of flows near the surface with a defect was used. In case of insignificant damage, it is possible to consider further use of the unit for its intended purpose, which may be important in the threatened period for states with a limited number of such products.

Authors

Institutions

Publication Details

Journal
Global Nuclear Safety
Published
2024-12-20
DOI
https://doi.org/10.26583/gns-2024-04-02
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technical condition assessment of a small-sized nuclear power plant after transportation unit overturning

О. А. Губеладзе, A. R. Gubeladze
Global Nuclear Safety
Engineering Diagnostics and Reliability
article

Technical condition assessment of a small-sized nuclear power plant after transportation unit overturning

О. А. Губеладзе, A. R. Gubeladze
article en

Abstract

The article considers the final stage of emergency development associated with the transport unit overturning with a small-sized nuclear power plant. Mathematical modelling allowed to obtain information about possible consequences. Among the most serious foreseeable damages are violations of the thermal protection coating in the area of the tip and bottom of the unit, which is a part of the separating head unit. To assess the unacceptability of this or that damage, the method of calculation of aerodynamic characteristics of flows near the surface with a defect was used. In case of insignificant damage, it is possible to consider further use of the unit for its intended purpose, which may be important in the threatened period for states with a limited number of such products.

Global Nuclear SafetyVol. 14(4)
Institute of Service and Entrepreneurship of DGTU (RU), Don State Technical University (RU)
Openalex Percentile: Top 73%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.