Quantification of beam size impact on intensity-modulated proton therapy with robust optimization in head and neck cancer—comparison with intensity-modulated radiation therapy

We assessed the effect of beam size on plan robustness for intensity-modulated proton therapy (IMPT) of head and neck cancer (HNC) and compared the plan quality including robustness with that of intensity-modulated radiation therapy (IMRT). IMPT plans were generated for six HNC patients using six beam sizes (air-sigma 3-17 mm at isocenter for a 70-230 MeV) and two optimization methods for planning target volume-based non-robust optimization (NRO) and clinical target volume (CTV)-based robust optimization (RO). Worst-case dosimetric parameters and plan robustness for CTV and organs-at-risk (OARs) were assessed under different scenarios, assuming a ± 1-5 mm setup error and a ± 3% range error. Statistical comparisons of NRO-IMPT, RO-IMPT and IMRT plans were performed. In regard to CTV-D99%, RO-IMPT with smaller beam size was more robust than RO-IMPT with larger beam sizes, whereas NRO-IMPT showed the opposite (P < 0.05). There was no significant difference in the robustness of the CTV-D99% and CTV-D95% between RO-IMPT and IMRT. The worst-case CTV coverage of IMRT (±5 mm/3%) for all patients was 96.0% ± 1.4% (D99%) and 97.9% ± 0.3% (D95%). For four out of six patients, the worst-case CTV-D95% for RO-IMPT (±1-5 mm/3%) were higher than those for IMRT. Compared with IMRT, RO-IMPT with smaller beam sizes achieved lower worst-case doses to OARs. In HNC treatment, utilizing smaller beam sizes in RO-IMPT improves plan robustness compared to larger beam sizes, achieving comparable target robustness and lower worst-case OARs doses compared to IMRT.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research
Published
2024-12-27
DOI
https://doi.org/10.1093/jrr/rrae097
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of beam size impact on intensity-modulated proton therapy with robust optimization in head and neck cancer—comparison with intensity-modulated radiation therapy

Kana Motegi, Hiromi Baba, Yuya Sugama, Takeji Sakae et al.
Journal of Radiation Research
Radiation Therapy and Dosimetry
article

Quantification of beam size impact on intensity-modulated proton therapy with robust optimization in head and neck cancer—comparison with intensity-modulated radiation therapy

Kana Motegi, Hiromi Baba, Yuya Sugama, Takeji Sakae, Ryo Takahashi, H. Tachibana, Kenji Hotta
article en

Abstract

We assessed the effect of beam size on plan robustness for intensity-modulated proton therapy (IMPT) of head and neck cancer (HNC) and compared the plan quality including robustness with that of intensity-modulated radiation therapy (IMRT). IMPT plans were generated for six HNC patients using six beam sizes (air-sigma 3-17 mm at isocenter for a 70-230 MeV) and two optimization methods for planning target volume-based non-robust optimization (NRO) and clinical target volume (CTV)-based robust optimization (RO). Worst-case dosimetric parameters and plan robustness for CTV and organs-at-risk (OARs) were assessed under different scenarios, assuming a ± 1-5 mm setup error and a ± 3% range error. Statistical comparisons of NRO-IMPT, RO-IMPT and IMRT plans were performed. In regard to CTV-D99%, RO-IMPT with smaller beam size was more robust than RO-IMPT with larger beam sizes, whereas NRO-IMPT showed the opposite (P < 0.05). There was no significant difference in the robustness of the CTV-D99% and CTV-D95% between RO-IMPT and IMRT. The worst-case CTV coverage of IMRT (±5 mm/3%) for all patients was 96.0% ± 1.4% (D99%) and 97.9% ± 0.3% (D95%). For four out of six patients, the worst-case CTV-D95% for RO-IMPT (±1-5 mm/3%) were higher than those for IMRT. Compared with IMRT, RO-IMPT with smaller beam sizes achieved lower worst-case doses to OARs. In HNC treatment, utilizing smaller beam sizes in RO-IMPT improves plan robustness compared to larger beam sizes, achieving comparable target robustness and lower worst-case OARs doses compared to IMRT.

Journal of Radiation ResearchVol. 66(1)
University of Tsukuba (JP), National Cancer Center Hospital East (JP), Aizawa Hospital (JP)
Sustainable cities and communities, Good health and well-being
Openalex Percentile: Top 57%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.