Degradation Behavior of Coated Metallic Stents: Influence of In Vitro Fluid-Dynamic Biostability Testing Conditions

Coated metallic stents are the next generation of metallic stents with improved surface properties. To evaluate the degradation behavior of stents in vitro, different in vitro degradation models can be applied: (i) static immersion test: degradation under static fluid condition, (ii) fluid dynamic test: degradation under flowing fluid, and (iii) electrochemical corrosion test: degradation under the influence of electric potential. During these experimental procedures, stents interact with the simulated blood plasma, and degradation products are formed in the form of depositions on the stent surface, likewise in vivo experiments. These deposited crystals act as a hindrance to the application of important characterization techniques (e.g., mass loss measurement for the calculation of corrosion rate and examining the adhesion of the coating to metallic stents after fluid dynamic exposure). Therefore, to better characterize the coatings, the removal of these depositions is significant. In this work, we investigate the influence of in vitro test conditions in fluid dynamic biostability tests on the biostability of titanium oxynitride (TiO<sub>X</sub>N<sub>Y</sub>) coated stainless steel stents by adapting various fluid dynamic experimental parameters. The experimental conditions are based on modification in the components of fluid dynamic setup (e.g., tubings), simulated body fluid (SBF), with and without Ca<sup>++</sup> and Mg<sup>++</sup> ions, and the cleaning procedure (use of water, acetone, and isopropanol). Four different experiments were conducted under various experimental parameter sets. SEM and EDX measurements were used for the identification of degradation products after each experiment. This study highlights the importance of optimized experimental conditions showing negligible depositions when utilizing Puriflex tubing or a comparable artificial vessel, SBF devoid of Ca<sup>++</sup> and Mg<sup>++</sup> ions, and performing sample cleaning with distilled water in an ultrasonic bath. The presented conditions were optimized for titanium oxynitride coated samples. A similar approach could be applied to other samples with or without some small variation.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-12-26
DOI
https://doi.org/10.3390/ma18010046
Citations
2
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Degradation Behavior of Coated Metallic Stents: Influence of In Vitro Fluid-Dynamic Biostability Testing Conditions

Gianaurelio Cuniberti, Muhammad Saqib, Jörg Opitz, Natalia Beshchasna
2 citations
Materials
Corrosion Behavior and Inhibition
0.23
article

Degradation Behavior of Coated Metallic Stents: Influence of In Vitro Fluid-Dynamic Biostability Testing Conditions

Gianaurelio Cuniberti, Muhammad Saqib, Jörg Opitz, Natalia Beshchasna
article en
2 citations

Abstract

Coated metallic stents are the next generation of metallic stents with improved surface properties. To evaluate the degradation behavior of stents in vitro, different in vitro degradation models can be applied: (i) static immersion test: degradation under static fluid condition, (ii) fluid dynamic test: degradation under flowing fluid, and (iii) electrochemical corrosion test: degradation under the influence of electric potential. During these experimental procedures, stents interact with the simulated blood plasma, and degradation products are formed in the form of depositions on the stent surface, likewise in vivo experiments. These deposited crystals act as a hindrance to the application of important characterization techniques (e.g., mass loss measurement for the calculation of corrosion rate and examining the adhesion of the coating to metallic stents after fluid dynamic exposure). Therefore, to better characterize the coatings, the removal of these depositions is significant. In this work, we investigate the influence of in vitro test conditions in fluid dynamic biostability tests on the biostability of titanium oxynitride (TiO<sub>X</sub>N<sub>Y</sub>) coated stainless steel stents by adapting various fluid dynamic experimental parameters. The experimental conditions are based on modification in the components of fluid dynamic setup (e.g., tubings), simulated body fluid (SBF), with and without Ca<sup>++</sup> and Mg<sup>++</sup> ions, and the cleaning procedure (use of water, acetone, and isopropanol). Four different experiments were conducted under various experimental parameter sets. SEM and EDX measurements were used for the identification of degradation products after each experiment. This study highlights the importance of optimized experimental conditions showing negligible depositions when utilizing Puriflex tubing or a comparable artificial vessel, SBF devoid of Ca<sup>++</sup> and Mg<sup>++</sup> ions, and performing sample cleaning with distilled water in an ultrasonic bath. The presented conditions were optimized for titanium oxynitride coated samples. A similar approach could be applied to other samples with or without some small variation.

MaterialsVol. 18(1)
Max Bergmann Zentrum für Biomaterialien (DE), Fraunhofer Institute for Ceramic Technologies and Systems (DE), Technische Universität Dresden (DE)
Deutscher Akademischer Austauschdienst, Bundesministerium für Bildung und Forschung, Technische Universität Dresden, Graduiertenakademie, Technische Universität Dresden
Openalex Percentile: Top 49%
Corrosion Behavior and Inhibition
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.