Inverted supracondylar femoral dynamic compression plates for revision of construct failure following tibial cranial closing wedge ostectomy in three dogs

Construct failure is a rare complication of tibial cranial closing wedge ostectomy for the management of cranial cruciate ligament disease. Construct failure can present significant challenges for reconstruction. This case report describes three dogs with construct failure which were successfully revised by the repurposing of an inverted femoral supracondylar femoral plate as part of the revision. Data were obtained from the medical records and telephone update. The use of an inverted supracondylar plate in the proximal tibia generally had good outcomes for the management of bone implant failure following cranial closing wedge ostectomy and offers a hitherto undescribed technique using a low-cost and accessible implant for repair.

Authors

Institutions

Publication Details

Journal
Journal of Small Animal Practice
Published
2024-12-26
DOI
https://doi.org/10.1111/jsap.13817
Citations
1
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inverted supracondylar femoral dynamic compression plates for revision of construct failure following tibial cranial closing wedge ostectomy in three dogs

Richard Meeson, Simon P. Wells, Joshua Winter, M. J. Pead
1 citations
Journal of Small Animal Practice
Veterinary Orthopedics and Neurology
0.64
article

Inverted supracondylar femoral dynamic compression plates for revision of construct failure following tibial cranial closing wedge ostectomy in three dogs

Richard Meeson, Simon P. Wells, Joshua Winter, M. J. Pead
article en
1 citations

Abstract

Construct failure is a rare complication of tibial cranial closing wedge ostectomy for the management of cranial cruciate ligament disease. Construct failure can present significant challenges for reconstruction. This case report describes three dogs with construct failure which were successfully revised by the repurposing of an inverted femoral supracondylar femoral plate as part of the revision. Data were obtained from the medical records and telephone update. The use of an inverted supracondylar plate in the proximal tibia generally had good outcomes for the management of bone implant failure following cranial closing wedge ostectomy and offers a hitherto undescribed technique using a low-cost and accessible implant for repair.

Journal of Small Animal PracticeVol. 66(4)
Royal Veterinary College (GB)
Openalex Percentile: Top 25%
Veterinary Orthopedics and Neurology
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.