Development of Tracer Gas Method to Improve Indoor Air Quality: A Study on Ventilation Performance in Apartment Buildings in South Korea

This study analyzes the shortcomings of South Korea’s current evaluation method of ventilation performance for apartment buildings and suggests improvements. The current Korean regulations rely on the air change rate method, which is a prescriptive method and thus inadequately measures indoor air quality practically. Therefore, this study reviews various standards, finding that these standards can be categorized into those evaluating the mechanical performance of ventilators and those assessing indoor ventilation performance. This study highlights that the standards evaluating indoor ventilation performance are based on the tracer gas method but lack clear testing procedures and boundary conditions. This research also reviews the various previous research articles, noting that Korean research places emphasis on system design parameters, while international research focuses on architectural factors. It also identifies inconsistencies in the experimental setups across studies. To improve the current evaluation methods, the research suggests enhancing the tracer gas method with clear testing procedures and introducing indicators such as the age of air and uniformity coefficient together. Since the air change rate method does not consider the actual airflows and distribution in indoor spaces, this method is limited to deriving improvements in indoor ventilation performance. However, the suggested tracer gas method and indicators can be used to discover the optimal locations of vents for better indoor air quality or to drive a better building design to achieve better indoor ventilation performance. In other words, these enhancements aim to provide more accurate and comprehensive insights into the effectiveness of indoor ventilation systems, helping engineers, designers, and residents better understand and improve indoor air quality.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-12-26
DOI
https://doi.org/10.3390/buildings15010049
Citations
1
Primary Topic
Energy and Environmental Systems
Type
article
Field-Weighted Citation Impact
0.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Tracer Gas Method to Improve Indoor Air Quality: A Study on Ventilation Performance in Apartment Buildings in South Korea

Soo Man Lee, Gil Tae Kim, Byung Chang Kwag, Sangyoon Lee
1 citations
Buildings
Energy and Environmental Systems
0.68
article

Development of Tracer Gas Method to Improve Indoor Air Quality: A Study on Ventilation Performance in Apartment Buildings in South Korea

Soo Man Lee, Gil Tae Kim, Byung Chang Kwag, Sangyoon Lee
article en
1 citations

Abstract

This study analyzes the shortcomings of South Korea’s current evaluation method of ventilation performance for apartment buildings and suggests improvements. The current Korean regulations rely on the air change rate method, which is a prescriptive method and thus inadequately measures indoor air quality practically. Therefore, this study reviews various standards, finding that these standards can be categorized into those evaluating the mechanical performance of ventilators and those assessing indoor ventilation performance. This study highlights that the standards evaluating indoor ventilation performance are based on the tracer gas method but lack clear testing procedures and boundary conditions. This research also reviews the various previous research articles, noting that Korean research places emphasis on system design parameters, while international research focuses on architectural factors. It also identifies inconsistencies in the experimental setups across studies. To improve the current evaluation methods, the research suggests enhancing the tracer gas method with clear testing procedures and introducing indicators such as the age of air and uniformity coefficient together. Since the air change rate method does not consider the actual airflows and distribution in indoor spaces, this method is limited to deriving improvements in indoor ventilation performance. However, the suggested tracer gas method and indicators can be used to discover the optimal locations of vents for better indoor air quality or to drive a better building design to achieve better indoor ventilation performance. In other words, these enhancements aim to provide more accurate and comprehensive insights into the effectiveness of indoor ventilation systems, helping engineers, designers, and residents better understand and improve indoor air quality.

BuildingsVol. 15(1)
Korea Environment Institute (KR)
Korea Agency for Infrastructure Technology Advancement
Openalex Percentile: Top 20%
Energy and Environmental Systems
0.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.