Fabrication and Characterization of Syringe Carbon Paste Electrode for Electrochemical Measurement

This study aims to fabricate and characterize a syringe carbon paste electrode (SCPE) using K3Fe(CN)6 10 mM solution with cyclic voltammetry technique. Characterization is performed by varying pH (pH 4, 7, and 10) and scan rate (30 - 100 mV/s) so that the characteristics of SCPE can be observed. The K3Fe(CN)6 10 mM solution test results at various pH variations obtained the largest anodic peak current (Ipa) at pH 10 was 44.75 µA. The scan rate results at various pH showed linear results with the diffusion coefficient of 1.77 x 10-6 cm2/s, 1.65 x 10-6 cm2/s, and 2.50 x 10-6 cm2/s with r values of 0.9994, 0.9975, and 0.9992 for pH 4, pH 7, and pH 10 respectively. This indicated that a diffusion process controlled this system's mass transfer in various pH. The detection of nitrite ions at a concentration of 2 mM showed a clear oxidation peak, with the highest Ipa value of 61.28 µA in pH 7 buffer solution.

Authors

Institutions

Publication Details

Journal
Helium Journal of Science and Applied Chemistry
Published
2024-12-27
DOI
https://doi.org/10.33751/helium.v4i2.5
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication and Characterization of Syringe Carbon Paste Electrode for Electrochemical Measurement

Anom Cahyotomo, Dicky Annas, Mohammad Jihad Madiabu, Imas Solihat et al.
Helium Journal of Science and Applied Chemistry
Analytical Chemistry and Sensors
article

Fabrication and Characterization of Syringe Carbon Paste Electrode for Electrochemical Measurement

Anom Cahyotomo, Dicky Annas, Mohammad Jihad Madiabu, Imas Solihat, Ardina Purnama Tirta, Arie Pratama Putra
article en

Abstract

This study aims to fabricate and characterize a syringe carbon paste electrode (SCPE) using K3Fe(CN)6 10 mM solution with cyclic voltammetry technique. Characterization is performed by varying pH (pH 4, 7, and 10) and scan rate (30 - 100 mV/s) so that the characteristics of SCPE can be observed. The K3Fe(CN)6 10 mM solution test results at various pH variations obtained the largest anodic peak current (Ipa) at pH 10 was 44.75 µA. The scan rate results at various pH showed linear results with the diffusion coefficient of 1.77 x 10-6 cm2/s, 1.65 x 10-6 cm2/s, and 2.50 x 10-6 cm2/s with r values of 0.9994, 0.9975, and 0.9992 for pH 4, pH 7, and pH 10 respectively. This indicated that a diffusion process controlled this system's mass transfer in various pH. The detection of nitrite ions at a concentration of 2 mM showed a clear oxidation peak, with the highest Ipa value of 61.28 µA in pH 7 buffer solution.

Helium Journal of Science and Applied ChemistryVol. 4(2)
IPB University (ID)
Openalex Percentile: Top 73%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fabrication and Characterization of Syringe Carbon Paste Electrode for Electrochemical Measurement — Anom Cahyotomo, Dicky Annas, et al. · Helium Journal of Science and Applied Chemistry (2024) | TGRS Research Map | TGRS