High sound pressure piezoelectric micromachined ultrasonic transducers using sputtered potassium sodium niobate

This work presents air-coupled piezoelectric micromachined ultrasonic transducers (pMUTs) with high sound pressure level (SPL) under low-driving voltages by utilizing sputtered potassium sodium niobate K<sub>0.34</sub>Na<sub>0.66</sub>NbO<sub>3</sub> (KNN) films. A prototype single KNN pMUT has been tested to show a resonant frequency at 106.3 kHz under 4 V<sub>p-p</sub> with outstanding characteristics: (1) a large vibration amplitude of 3.74 μm/V, and (2) a high acoustic root mean square (RMS) sound pressure level of 105.5 dB/V at 10 cm, which is 5-10 times higher than those of AlN-based pMUTs at a similar frequency. There are various potential sensing and actuating applications, such as fingerprint sensing, touch point, and gesture recognition. In this work, we present demonstrations in three fields: haptics, loudspeakers, and rangefinders. For haptics, an array of 15 × 15 KNN pMUTs is used as a non-contact actuator to provide a focal pressure of around 160.3 dB RMS SPL at a distance of 15 mm. This represents the highest output pressure achieved by an airborne pMUT for haptic sensation on human palms. When used as a loudspeaker, a single pMUT element with a resonant frequency close to the audible range at 22.8 kHz is characterized. It is shown to be able to generate a uniform acoustic output with an amplitude modulation scheme. In the rangefinder application, pulse-echo measurements using a single pMUT element demonstrate good transceiving results, capable of detecting objects up to 2.82 m away. As such, this new class of high-SPL and low-driving-voltage pMUTs could be further extended to other applications requiring high acoustic pressure and a small form factor.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2024-12-27
DOI
https://doi.org/10.1038/s41378-024-00841-y
Citations
8
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
2.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High sound pressure piezoelectric micromachined ultrasonic transducers using sputtered potassium sodium niobate

Yande Peng, Wei Yue, Lane W. Martin, Megan Teng et al.
8 citations
Microsystems & Nanoengineering
Ultrasonics and Acoustic Wave Propagation
2.15
article

High sound pressure piezoelectric micromachined ultrasonic transducers using sputtered potassium sodium niobate

Yande Peng, Wei Yue, Lane W. Martin, Megan Teng, Megha Acharya, Fan Xia, Sedat Pala, Xiaobing Yu, Liwei Lin, Yuanzheng Ma, Chunming Chen, Mingze Luo, Ryuichi Arakawa
article en
8 citations

Abstract

This work presents air-coupled piezoelectric micromachined ultrasonic transducers (pMUTs) with high sound pressure level (SPL) under low-driving voltages by utilizing sputtered potassium sodium niobate K<sub>0.34</sub>Na<sub>0.66</sub>NbO<sub>3</sub> (KNN) films. A prototype single KNN pMUT has been tested to show a resonant frequency at 106.3 kHz under 4 V<sub>p-p</sub> with outstanding characteristics: (1) a large vibration amplitude of 3.74 μm/V, and (2) a high acoustic root mean square (RMS) sound pressure level of 105.5 dB/V at 10 cm, which is 5-10 times higher than those of AlN-based pMUTs at a similar frequency. There are various potential sensing and actuating applications, such as fingerprint sensing, touch point, and gesture recognition. In this work, we present demonstrations in three fields: haptics, loudspeakers, and rangefinders. For haptics, an array of 15 × 15 KNN pMUTs is used as a non-contact actuator to provide a focal pressure of around 160.3 dB RMS SPL at a distance of 15 mm. This represents the highest output pressure achieved by an airborne pMUT for haptic sensation on human palms. When used as a loudspeaker, a single pMUT element with a resonant frequency close to the audible range at 22.8 kHz is characterized. It is shown to be able to generate a uniform acoustic output with an amplitude modulation scheme. In the rangefinder application, pulse-echo measurements using a single pMUT element demonstrate good transceiving results, capable of detecting objects up to 2.82 m away. As such, this new class of high-SPL and low-driving-voltage pMUTs could be further extended to other applications requiring high acoustic pressure and a small form factor.

Microsystems & NanoengineeringVol. 10(1)
Rice University (US), Southeast University (CN), Xi'an Jiaotong University (CN), University of California, Berkeley (US), Tsinghua University (CN)
National Science Foundation, British Society for Antimicrobial Chemotherapy, Division of Electrical, Communications and Cyber Systems
Affordable and clean energy
Openalex Percentile: Top 13%
Ultrasonics and Acoustic Wave Propagation
2.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.