The external controller solutions (ECS) based on programmable logic controller with humanmachine interface: A case study for the water level simulator plant

The External Controller Solutions (ECS) is designed with the flexibility and able to be integrated with various plants. The ECS has been built using PLC and HMI. Several tests have been carried out in developing this ECS, including testing Digital Input/Output (DI/DO) and Analog Input/Output (AI/AO) voltages. This ECS be able to control up-to 8 devices simultaneously with the data refresh time interval of 100 ms and be able to handle up-to 10,000 operating cycles within 24 hours without significant performance degradation. ECS performance is very good, proven by the results showing that the system runs well within 20-35 °C of temperatures range and 20%-80% of humidity. To show the advantage of ECS, it has already been integrated on the Water Level Simulator (WLS) plant and successfully controlled the flow through the VSD at 54 RPM/Hz in range of 15-30 Hz.

Authors

Institutions

Publication Details

Journal
Jurnal Nasional Aplikasi Mekatronika Otomasi dan Robot Industri (AMORI)
Published
2024-12-27
DOI
https://doi.org/10.12962/j27213560.v3i2.21918
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The external controller solutions (ECS) based on programmable logic controller with humanmachine interface: A case study for the water level simulator plant

Safira Firdaus Mujiyanti, Dwi Oktavianto Wahyu Nugroho, Sefi Novendra Patrialova, Ahmad Fauzan Adziima et al.
Jurnal Nasional Aplikasi Mekatronika Otomasi dan Robot Industri (AMORI)
Power Line Communications and Noise
article

The external controller solutions (ECS) based on programmable logic controller with humanmachine interface: A case study for the water level simulator plant

Safira Firdaus Mujiyanti, Dwi Oktavianto Wahyu Nugroho, Sefi Novendra Patrialova, Ahmad Fauzan Adziima, Waga Winata
article en

Abstract

The External Controller Solutions (ECS) is designed with the flexibility and able to be integrated with various plants. The ECS has been built using PLC and HMI. Several tests have been carried out in developing this ECS, including testing Digital Input/Output (DI/DO) and Analog Input/Output (AI/AO) voltages. This ECS be able to control up-to 8 devices simultaneously with the data refresh time interval of 100 ms and be able to handle up-to 10,000 operating cycles within 24 hours without significant performance degradation. ECS performance is very good, proven by the results showing that the system runs well within 20-35 °C of temperatures range and 20%-80% of humidity. To show the advantage of ECS, it has already been integrated on the Water Level Simulator (WLS) plant and successfully controlled the flow through the VSD at 54 RPM/Hz in range of 15-30 Hz.

Jurnal Nasional Aplikasi Mekatronika Otomasi dan Robot Industri (AMORI)Vol. 3(2)
Sepuluh Nopember Institute of Technology (ID)
Institut Teknologi Sepuluh Nopember
Clean water and sanitation
Openalex Percentile: Top 78%
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.