Uniform Vibrotactile Rendering in a Haptic Ultrasound Probe

This study investigates the integration of haptic feedback into ultrasound probes to achieve uniform vibrotactile rendering on the grip surface used by clinicians, while minimizing vibrations on the diagnostic surface that contacts the patient. This method enables clinicians to experience consistent vibrotactile feedback regardless of grip variation, preserving measurement accuracy and enhancing patient comfort. Frequency Response Function(FRF) techniques were employed to optimize actuator control, effectively minimizing vibrations on the diagnostic surface and achieving uniform vibrotactile rendering. To validate this approach, a prototype ultrasound probe was fabricated using 3D printing. FRF measurements were taken with a laser Doppler vibrometer, and optimized actuator control signals were applied. Results showed that vibrations on the diagnostic surface remained below the target threshold of 0.2 G, while delivering uniform vibrotactile rendering in the 1 G ~ 2 G range on the grip surface.

Authors

Publication Details

Journal
Transactions of the Korean Society for Noise and Vibration Engineering
Published
2024-12-20
DOI
https://doi.org/10.5050/ksnve.2024.34.6.652
Primary Topic
Tactile and Sensory Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uniform Vibrotactile Rendering in a Haptic Ultrasound Probe

Wheejae Kim, No‐Cheol Park, Ji-Young Cha, Youngjin Park
Transactions of the Korean Society for Noise and Vibration Engineering
Tactile and Sensory Interactions
article

Uniform Vibrotactile Rendering in a Haptic Ultrasound Probe

Wheejae Kim, No‐Cheol Park, Ji-Young Cha, Youngjin Park
article en

Abstract

This study investigates the integration of haptic feedback into ultrasound probes to achieve uniform vibrotactile rendering on the grip surface used by clinicians, while minimizing vibrations on the diagnostic surface that contacts the patient. This method enables clinicians to experience consistent vibrotactile feedback regardless of grip variation, preserving measurement accuracy and enhancing patient comfort. Frequency Response Function(FRF) techniques were employed to optimize actuator control, effectively minimizing vibrations on the diagnostic surface and achieving uniform vibrotactile rendering. To validate this approach, a prototype ultrasound probe was fabricated using 3D printing. FRF measurements were taken with a laser Doppler vibrometer, and optimized actuator control signals were applied. Results showed that vibrations on the diagnostic surface remained below the target threshold of 0.2 G, while delivering uniform vibrotactile rendering in the 1 G ~ 2 G range on the grip surface.

Transactions of the Korean Society for Noise and Vibration EngineeringVol. 34(6)
Openalex Percentile: Top 75%
Tactile and Sensory Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Uniform Vibrotactile Rendering in a Haptic Ultrasound Probe — Wheejae Kim, No‐Cheol Park, et al. · Transactions of the Korean Society for Noise and Vibration Engineering (2024) | TGRS Research Map | TGRS