Development of a novel electro-mechanical brake motor thermal management system for nonuniform heating under extreme thermal conditions

• Study investigated cooling performance of EMB motor under extreme conditions. • Simulations designed to analyze heat transfer and evaluate various cooling methods. • SAT type phase-change material demonstrated the best cooling performance. • Findings suggest Hybrid cooling method provides most effective cooling performance. • Hybrid cooling performance remained consistently reliable under many scenarios. A challenge currently faced by automotive brake systems industry is the development of electromechanical brakes that need to overcome the impact of frictional heat on the motor performance. However, previous studies that examined motor cooling performance have been conducted in surrounding air temperatures below 80°C while considering uniform coil heat generation. These assumptions are not valid for EMB systems. This study conducted experiments that considered extreme surrounding temperature conditions and nonuniform coil heat generation. Based on the results of these experiments, a hybrid cooling system that can withstand extreme thermal conditions is proposed through simulation. The Hybrid cooling method that uses heat sinks, insulation, and phase change materials is the most effective with a reduction in the maximum coil temperature of 23 K. Moreover, Hybrid cooling attained maximum temperature of 137.1°C even in the most extreme 1-phase motor control strategy, which is 22.8 K lower than the Baseline. When tested for pad friction coefficient ranges from 0.3 to 0.5, the system operated below the target temperature reaching up to 139.9°C under the most extreme 0.31 conditions. This study shows that effective thermal management of electromechanical brake systems that ensures system durability and reliability of driver safety is achievable.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2024-12-26
DOI
https://doi.org/10.1016/j.enconman.2024.119406
Citations
9
Primary Topic
Brake Systems and Friction Analysis
Type
article
Field-Weighted Citation Impact
1.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a novel electro-mechanical brake motor thermal management system for nonuniform heating under extreme thermal conditions

Hongseok Choi, Piljun Park, Hoseong Lee, Sangwook Lee et al.
9 citations
Energy Conversion and Management
Brake Systems and Friction Analysis
1.83
article

Development of a novel electro-mechanical brake motor thermal management system for nonuniform heating under extreme thermal conditions

Hongseok Choi, Piljun Park, Hoseong Lee, Sangwook Lee, S.C. Jeong
article en
9 citations

Abstract

• Study investigated cooling performance of EMB motor under extreme conditions. • Simulations designed to analyze heat transfer and evaluate various cooling methods. • SAT type phase-change material demonstrated the best cooling performance. • Findings suggest Hybrid cooling method provides most effective cooling performance. • Hybrid cooling performance remained consistently reliable under many scenarios. A challenge currently faced by automotive brake systems industry is the development of electromechanical brakes that need to overcome the impact of frictional heat on the motor performance. However, previous studies that examined motor cooling performance have been conducted in surrounding air temperatures below 80°C while considering uniform coil heat generation. These assumptions are not valid for EMB systems. This study conducted experiments that considered extreme surrounding temperature conditions and nonuniform coil heat generation. Based on the results of these experiments, a hybrid cooling system that can withstand extreme thermal conditions is proposed through simulation. The Hybrid cooling method that uses heat sinks, insulation, and phase change materials is the most effective with a reduction in the maximum coil temperature of 23 K. Moreover, Hybrid cooling attained maximum temperature of 137.1°C even in the most extreme 1-phase motor control strategy, which is 22.8 K lower than the Baseline. When tested for pad friction coefficient ranges from 0.3 to 0.5, the system operated below the target temperature reaching up to 139.9°C under the most extreme 0.31 conditions. This study shows that effective thermal management of electromechanical brake systems that ensures system durability and reliability of driver safety is achievable.

Energy Conversion and ManagementVol. 325
Hyundai Mobis (South Korea) (KR), Korea University (KR), Korea University (JP)
Ministry of Trade, Industry and Energy
Affordable and clean energy
Openalex Percentile: Top 15%
Brake Systems and Friction Analysis
1.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.