Design, development and performance evaluation of mobile street cleaner (mSC) for municipal solid waste litter management

Rapid urbanization and population growth have led to a significant rise in municipal solid waste litter (MSWL) generation. The traditional manual collection process are labour-intensive, time-consuming, and often inadequate for addressing the growing volume of MSWL in cities. Advanced vacuum suction devices (VSDs) have emerged as an effective solution for indoor litter collection. However, limited studies has been reported to understand the feasibility of these devices for outdoor applications. Therefore, this study proposes a mobile street cleaner (mSC), a VSD specifically designed and engineered for MSWL collection from diverse urban settings. The study highlights the design methodology and model assumptions for developing a mechanical suction unit (MSU) for the mSC, demonstrating a 70% performance efficacy at 5000 m³/h (S 1 ) suction flow rate. Batch-scale experimental simulations with varying hose pipe diameter (D) (0.3–0.15 m), suction flow rate (S) (2500–5000 m 3 /h) and litter characteristic was conducted to optimize mSC. At S 1 , the nozzle inlet velocity of 23–40 m/s was found to be more effective in collecting larger and heavier litter particles compared to S 2 . Therefore, the hose pipe diameter of 0.25 (D 2 ) and 0.20 m (D 3 ) at S 1 was found to be most efficient and less time consuming in MSWL collection. Finally, the study highlights the potential benefits of proposed mSC in automating collection process, reducing operational costs, improving source segregation and recycling opportunities. The findings of this study offer valuable insights for technocrats and researchers in enhancing application of VSDs for sustainable urban waste management . • Developed a mobile street cleaner (mSC) for municipal solid waste litter collection. • Centrifugal air blower had maximum suction rate of 5000 m³/h at 70.45% efficacy. • Power consumption rate was found to be varying from 2.86 to 1.59 KWh • Optimized hose pipe diameter (0.3–0.15 m) and suction rate (2500–5000 m 3 /h) for mSC.

Authors

Institutions

Publication Details

Journal
Sustainable Chemistry and Pharmacy
Published
2024-12-26
DOI
https://doi.org/10.1016/j.scp.2024.101889
Citations
1
Primary Topic
Municipal Solid Waste Management
Type
article
Field-Weighted Citation Impact
0.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design, development and performance evaluation of mobile street cleaner (mSC) for municipal solid waste litter management

Anil Kumar Dikshit, Sunil Kumar, Deval Singh
1 citations
Sustainable Chemistry and Pharmacy
Municipal Solid Waste Management
0.29
article

Design, development and performance evaluation of mobile street cleaner (mSC) for municipal solid waste litter management

Anil Kumar Dikshit, Sunil Kumar, Deval Singh
article en
1 citations

Abstract

Rapid urbanization and population growth have led to a significant rise in municipal solid waste litter (MSWL) generation. The traditional manual collection process are labour-intensive, time-consuming, and often inadequate for addressing the growing volume of MSWL in cities. Advanced vacuum suction devices (VSDs) have emerged as an effective solution for indoor litter collection. However, limited studies has been reported to understand the feasibility of these devices for outdoor applications. Therefore, this study proposes a mobile street cleaner (mSC), a VSD specifically designed and engineered for MSWL collection from diverse urban settings. The study highlights the design methodology and model assumptions for developing a mechanical suction unit (MSU) for the mSC, demonstrating a 70% performance efficacy at 5000 m³/h (S 1 ) suction flow rate. Batch-scale experimental simulations with varying hose pipe diameter (D) (0.3–0.15 m), suction flow rate (S) (2500–5000 m 3 /h) and litter characteristic was conducted to optimize mSC. At S 1 , the nozzle inlet velocity of 23–40 m/s was found to be more effective in collecting larger and heavier litter particles compared to S 2 . Therefore, the hose pipe diameter of 0.25 (D 2 ) and 0.20 m (D 3 ) at S 1 was found to be most efficient and less time consuming in MSWL collection. Finally, the study highlights the potential benefits of proposed mSC in automating collection process, reducing operational costs, improving source segregation and recycling opportunities. The findings of this study offer valuable insights for technocrats and researchers in enhancing application of VSDs for sustainable urban waste management . • Developed a mobile street cleaner (mSC) for municipal solid waste litter collection. • Centrifugal air blower had maximum suction rate of 5000 m³/h at 70.45% efficacy. • Power consumption rate was found to be varying from 2.86 to 1.59 KWh • Optimized hose pipe diameter (0.3–0.15 m) and suction rate (2500–5000 m 3 /h) for mSC.

Sustainable Chemistry and PharmacyVol. 43
Indian Institute of Technology Bombay (IN), National Environmental Engineering Research Institute (IN)
Sustainable cities and communities, Industry, innovation and infrastructure
Openalex Percentile: Top 36%
Municipal Solid Waste Management
0.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.