Short-term memory artificial neural network modelling to predict concrete corrosion in wastewater treatment plant inlet chambers using sulphide sensors

Sulphide accumulation in lengthy rising mains can lead to significant concrete corrosion and odour issues at manholes and wastewater treatment plants (WWTPs). Monitoring dissolved sulphide, typically relies on auto-sampling or grab samples followed by laboratory analysis, remains underdeveloped. This study aimed to identify sources of concrete corrosion sources at a WWTP inlet chamber and develop a sulphide prediction model using artificial intelligence (AI). A dissolved sulphide sensor was installed at three rising mains (RM1 to RM3) and the combined inlet at a full-scale WWTP, providing a 5-minute resolution data that revealed a daily hydrogen sulphide (H 2 S) pattern that inversely correlated with the flow rate. RM1 exhibited the highest sulphide load, peaking at 3.6 kg/d during cold months and 4.2 kg/d during warm months. RM3 and RM2 recorded loads of 2.96 kg/d and 0.98 kg/d, respectively, during cold months. A long short-term memory (LSTM) artificial neural network (ANN) model was developed to predict H₂S concentrations at RM1, using flow rate, temperature, and time of day as inputs. The model achieved a root mean square error (RMSE) of 0.34 and a Nash-Sutcliffe efficiency (NSE) of 0.57, accurately predicting the daily H 2 S pattern. This study's main contributions include insights into sulphide dynamics from high-resolution sensor data, which could support corrosion management as part of a septicity warning system or feedforward control for sulphide treatment. Additionally, the AI-based prediction model offers potential for sensor repurposing, saving both capital and operational costs. • Sulphide accumulation causes corrosion and odour in rising mains and WWTPs. • Study installed novel sensor revealing daily H 2 S patterns. • Artificial neural network predicted H 2 S concentrations accurately. • Monitoring sulphide with AI was effective and could lead to cost savings. • Methodology proposed enables the understanding of sulphide dynamics in rising mains.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2024-12-26
DOI
https://doi.org/10.1016/j.jwpe.2024.106821
Citations
3
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short-term memory artificial neural network modelling to predict concrete corrosion in wastewater treatment plant inlet chambers using sulphide sensors

Yadira Bajón-Fernández, J. Mendizabal, Ben Martin, Ana Soares et al.
3 citations
Journal of Water Process Engineering
Air Quality Monitoring and Forecasting
0.62
article

Short-term memory artificial neural network modelling to predict concrete corrosion in wastewater treatment plant inlet chambers using sulphide sensors

Yadira Bajón-Fernández, J. Mendizabal, Ben Martin, Ana Soares, David H. Vernon
article en
3 citations

Abstract

Sulphide accumulation in lengthy rising mains can lead to significant concrete corrosion and odour issues at manholes and wastewater treatment plants (WWTPs). Monitoring dissolved sulphide, typically relies on auto-sampling or grab samples followed by laboratory analysis, remains underdeveloped. This study aimed to identify sources of concrete corrosion sources at a WWTP inlet chamber and develop a sulphide prediction model using artificial intelligence (AI). A dissolved sulphide sensor was installed at three rising mains (RM1 to RM3) and the combined inlet at a full-scale WWTP, providing a 5-minute resolution data that revealed a daily hydrogen sulphide (H 2 S) pattern that inversely correlated with the flow rate. RM1 exhibited the highest sulphide load, peaking at 3.6 kg/d during cold months and 4.2 kg/d during warm months. RM3 and RM2 recorded loads of 2.96 kg/d and 0.98 kg/d, respectively, during cold months. A long short-term memory (LSTM) artificial neural network (ANN) model was developed to predict H₂S concentrations at RM1, using flow rate, temperature, and time of day as inputs. The model achieved a root mean square error (RMSE) of 0.34 and a Nash-Sutcliffe efficiency (NSE) of 0.57, accurately predicting the daily H 2 S pattern. This study's main contributions include insights into sulphide dynamics from high-resolution sensor data, which could support corrosion management as part of a septicity warning system or feedforward control for sulphide treatment. Additionally, the AI-based prediction model offers potential for sensor repurposing, saving both capital and operational costs. • Sulphide accumulation causes corrosion and odour in rising mains and WWTPs. • Study installed novel sensor revealing daily H 2 S patterns. • Artificial neural network predicted H 2 S concentrations accurately. • Monitoring sulphide with AI was effective and could lead to cost savings. • Methodology proposed enables the understanding of sulphide dynamics in rising mains.

Journal of Water Process EngineeringVol. 69
Thames Water (United Kingdom) (GB), Cranfield University (GB)
Thames Water, Engineering and Physical Sciences Research Council
Clean water and sanitation
Openalex Percentile: Top 34%
Air Quality Monitoring and Forecasting
0.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.