Precision blood pressure prediction leveraging Photoplethysmograph signals using Support Vector Regression

To facilitate the operation of more sophisticated medical robots, blood pressure prediction technology was developed using Photoplethysmograph (PPG) signals from a single finger, using the Support Vector Regression (SVR) method. The data collection process involved 110 participants aged 20 to 70 years for modeling and validation. The model training phase was carried out with various parameter variations to obtain the optimal model based on the Mean Absolute Error (MAE) value. The blood pressure estimation results showed an average error of around 2.78 mmHg for systolic pressure and 7.34 mmHg for diastolic pressure. Validation on 30 new participants revealed a slight increase in the average error, which was around 4.23 mmHg (with 93.90 % accuracy) for systolic pressure and 5.12 mmHg (with 96.64 % accuracy) for diastolic pressure. These results, which are characterized by a low error rate, indicate that the SVR model is able to predict blood pressure accurately and consistently, both on training data and new data that was previously unseen.

Authors

Publication Details

Journal
Egyptian Informatics Journal
Published
2024-12-26
DOI
https://doi.org/10.1016/j.eij.2024.100599
Citations
7
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision blood pressure prediction leveraging Photoplethysmograph signals using Support Vector Regression

Dwi Esti Kusumandari, Mohammad Taufik, Arjon Turnip
7 citations
Egyptian Informatics Journal
Non-Invasive Vital Sign Monitoring
1.29
article

Precision blood pressure prediction leveraging Photoplethysmograph signals using Support Vector Regression

Dwi Esti Kusumandari, Mohammad Taufik, Arjon Turnip
article en
7 citations

Abstract

To facilitate the operation of more sophisticated medical robots, blood pressure prediction technology was developed using Photoplethysmograph (PPG) signals from a single finger, using the Support Vector Regression (SVR) method. The data collection process involved 110 participants aged 20 to 70 years for modeling and validation. The model training phase was carried out with various parameter variations to obtain the optimal model based on the Mean Absolute Error (MAE) value. The blood pressure estimation results showed an average error of around 2.78 mmHg for systolic pressure and 7.34 mmHg for diastolic pressure. Validation on 30 new participants revealed a slight increase in the average error, which was around 4.23 mmHg (with 93.90 % accuracy) for systolic pressure and 5.12 mmHg (with 96.64 % accuracy) for diastolic pressure. These results, which are characterized by a low error rate, indicate that the SVR model is able to predict blood pressure accurately and consistently, both on training data and new data that was previously unseen.

Egyptian Informatics JournalVol. 29
Openalex Percentile: Top 21%
Non-Invasive Vital Sign Monitoring
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.