Economic and environmental impacts of different ventilation systems in detached rural houses in severe cold climate

The growing demand for energy efficient and environmentally friendly buildings with improved comfort drives the need for advanced ventilation systems. Chinese rural houses in severe cold climate struggle with inadequate ventilation in winter, while the extremely low temperatures and huge heating demands hinder the effective implementation of mechanical ventilation. This study aims to identify the optimal ventilation system for rural detached houses in severe cold climate by examining the potential combination of earth-air heat exchanger and heat recovery, as well as comparing this system to other common ventilation solutions. Using a case building in Harbin, four mechanical ventilation configurations were simulated with IDA ICE. A multi-objective evaluation combining economic and environmental factors was employed to design the earth-air heat exchanger and evaluate different ventilation options. Results show that integrating an earth-air heat exchanger into a balanced ventilation notably reduces ventilation heating demand by 64 %, with its effectiveness particularly pronounced in colder conditions. Among all mechanical ventilation options, the balanced ventilation with both heat recovery and earth-air heat exchanger achieves the lowest CO 2 emissions at 44 kg CO 2 /m 2 . Exhaust ventilation emerges as the most cost-effective option. These findings illuminate the earth-air heat exchanger's heating performance in severe cold climate. Practical recommendations balancing economic effectiveness and environmental impacts were provided to guide the design of sustainable mechanical ventilation systems for detached rural houses in extreme climatic conditions. • Investigating ventilation options for detached houses in severe cold climate. • Applying simulation-based multi-objective evaluation. • Reducing ventilation heating demand by 64 % using an earth-air heat exchanger. • Noticeable heating performance of earth-air heat exchanger in colder conditions. • Exhaust ventilation proving life-cycle economically advantageous.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2024-12-26
DOI
https://doi.org/10.1016/j.jobe.2024.111689
Citations
2
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.53

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Economic and environmental impacts of different ventilation systems in detached rural houses in severe cold climate

Xinyi Hu, Matti Lehtonen, Risto Kosonen, Juha Jokisalo
2 citations
Journal of Building Engineering
Building Energy and Comfort Optimization
0.53
article

Economic and environmental impacts of different ventilation systems in detached rural houses in severe cold climate

Xinyi Hu, Matti Lehtonen, Risto Kosonen, Juha Jokisalo
article en
2 citations

Abstract

The growing demand for energy efficient and environmentally friendly buildings with improved comfort drives the need for advanced ventilation systems. Chinese rural houses in severe cold climate struggle with inadequate ventilation in winter, while the extremely low temperatures and huge heating demands hinder the effective implementation of mechanical ventilation. This study aims to identify the optimal ventilation system for rural detached houses in severe cold climate by examining the potential combination of earth-air heat exchanger and heat recovery, as well as comparing this system to other common ventilation solutions. Using a case building in Harbin, four mechanical ventilation configurations were simulated with IDA ICE. A multi-objective evaluation combining economic and environmental factors was employed to design the earth-air heat exchanger and evaluate different ventilation options. Results show that integrating an earth-air heat exchanger into a balanced ventilation notably reduces ventilation heating demand by 64 %, with its effectiveness particularly pronounced in colder conditions. Among all mechanical ventilation options, the balanced ventilation with both heat recovery and earth-air heat exchanger achieves the lowest CO 2 emissions at 44 kg CO 2 /m 2 . Exhaust ventilation emerges as the most cost-effective option. These findings illuminate the earth-air heat exchanger's heating performance in severe cold climate. Practical recommendations balancing economic effectiveness and environmental impacts were provided to guide the design of sustainable mechanical ventilation systems for detached rural houses in extreme climatic conditions. • Investigating ventilation options for detached houses in severe cold climate. • Applying simulation-based multi-objective evaluation. • Reducing ventilation heating demand by 64 % using an earth-air heat exchanger. • Noticeable heating performance of earth-air heat exchanger in colder conditions. • Exhaust ventilation proving life-cycle economically advantageous.

Journal of Building EngineeringVol. 99
Nanjing Tech University (CN), Aalto University (FI)
China Scholarship Council
Climate action
Openalex Percentile: Top 32%
Building Energy and Comfort Optimization
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.