Hybrid control of hydraulic directional valves: Integrating physics-based and data-driven models for enhanced accuracy and efficiency
In this paper, we tackle the challenge of accurately controlling the position of the valve spool in hydraulic 4/3 two-stage directional control valves utilized in mobile applications. The pilot valve's overlapping design often leads to a significant dead zone, negatively impacting positioning accuracy and necessitating a sophisticated controller design. To overcome these challenges, we introduce a control strategy founded on a control-oriented model. This model enables systematic compensation for the dead zone, pressure-induced flow fluctuations, and the solenoid's nonlinearities, optimizing the valve's operation for enhanced tracking performance, as verified by test bench measurements. Addressing the limitations inherent in traditional physics-based design methodologies, we suggest approximating the system's primary nonlinearities with a data-driven surrogate model. We propose a solution tailored for systems that rely on minimal sensor information. By merging the advantages of both physics-based and data-driven models, we formulate a hybrid control strategy. This comprehensive approach not only ensures high tracking performance but also has the potential to expedite the commissioning process for new valve variants.
Authors
- Matthias Bitzer
- Tobias Glück (ORCID: https://orcid.org/0000-0003-1497-6138)
- Adrian Trachte
- Amadeus Lobe (ORCID: https://orcid.org/0000-0003-2293-2928)
- Wolfgang Kemmetmüller (ORCID: https://orcid.org/0000-0001-7825-5917)
Institutions
- AIT Austrian Institute of Technology GmbH (AT)
- TU Wien (AT)
- Robert Bosch (Netherlands) (NL)
Publication Details
- Journal
- ISA Transactions
- Published
- 2024-12-26
- DOI
- https://doi.org/10.1016/j.isatra.2024.12.029
- Citations
- 7
- Primary Topic
- Hydraulic and Pneumatic Systems
- Type
- article
- Field-Weighted Citation Impact
- 1.49