Integrated Wearable Flexible Hydrogel Patch Sensing System for the Detection of Physiological Markers

Conventional wearable flexible sensing systems typically comprise three components: a flexible substrate that contacts the skin, a signal processing module, and a signal output module. These components function relatively independently, resulting in a complex system that lacks sufficient integration. Therefore, developing an integrated wearable flexible sensing system by combining the flexible substrate, the signal processing module, and the signal output module not only enhances performance and comfort, but also reduces manufacturing costs and the risk of failure. Hydrogel substrates are particularly advantageous due to their excellent biocompatibility, flexibility, and encapsulation capabilities. Herein, we designed an integrated wearable flexible sensing system using an agarose hydrogel to encapsulate biological oxidative enzymes (e.g., glucose oxidase (GOx), lactate oxidase, and ethanol oxidase) and silver nanowires-polydopamine (Ag NWs-PB) as the signal processing module and a color-changing TMB probe as the signal output module. Additionally, we incorporated a polydimethylsiloxane-silicon dioxide patch to collect sweat for detecting physiological markers (e.g., glucose, lactate, and ethanol). An example of the application to facilitate visual detection of glucose in sweat was developed by encapsulating GOx as a biological oxidative enzyme in a sensing system. The system provides results within 3.5 min and operates within a linear range of 0.02 to 5.00 mmol/L, achieving a limit of detection of 0.011 mmol/L. This innovation not only presents a more integrated and portable solution for wearable hydrogel systems, but also introduces a new, feasible method for detecting human physiological markers through a straightforward detection process.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-12-26
DOI
https://doi.org/10.1021/acs.analchem.4c05553
Citations
5
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated Wearable Flexible Hydrogel Patch Sensing System for the Detection of Physiological Markers

Zhiying Shao, Cunhao Fan, Xujing Feng, Kun Wang et al.
5 citations
Analytical Chemistry
Advanced Sensor and Energy Harvesting Materials
0.92
article

Integrated Wearable Flexible Hydrogel Patch Sensing System for the Detection of Physiological Markers

Zhiying Shao, Cunhao Fan, Xujing Feng, Kun Wang, Jie Wei, Huadong Heng, Kezuo Di
article en
5 citations

Abstract

Conventional wearable flexible sensing systems typically comprise three components: a flexible substrate that contacts the skin, a signal processing module, and a signal output module. These components function relatively independently, resulting in a complex system that lacks sufficient integration. Therefore, developing an integrated wearable flexible sensing system by combining the flexible substrate, the signal processing module, and the signal output module not only enhances performance and comfort, but also reduces manufacturing costs and the risk of failure. Hydrogel substrates are particularly advantageous due to their excellent biocompatibility, flexibility, and encapsulation capabilities. Herein, we designed an integrated wearable flexible sensing system using an agarose hydrogel to encapsulate biological oxidative enzymes (e.g., glucose oxidase (GOx), lactate oxidase, and ethanol oxidase) and silver nanowires-polydopamine (Ag NWs-PB) as the signal processing module and a color-changing TMB probe as the signal output module. Additionally, we incorporated a polydimethylsiloxane-silicon dioxide patch to collect sweat for detecting physiological markers (e.g., glucose, lactate, and ethanol). An example of the application to facilitate visual detection of glucose in sweat was developed by encapsulating GOx as a biological oxidative enzyme in a sensing system. The system provides results within 3.5 min and operates within a linear range of 0.02 to 5.00 mmol/L, achieving a limit of detection of 0.011 mmol/L. This innovation not only presents a more integrated and portable solution for wearable hydrogel systems, but also introduces a new, feasible method for detecting human physiological markers through a straightforward detection process.

Analytical ChemistryVol. 97(1)
Jiangsu University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 27%
Advanced Sensor and Energy Harvesting Materials
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.