Contribution to the calibration of current transformers with a rated secondary current of less than 1A

Standardized values of current transformers with the rated secondary currents of 5 A and 1 A are defined according to the requirements of analog measuring and relay techniques that were typical for the technology of the last century. The development of microprocessor technics and technology as well as digitalization processes in transmission and distribution sectors of power industry requires rated secondary currents of current transformers of less than 1A. That implies different technical and technology difficulties in manufacturing such transformers as well as its accuracy testing. This paper is contribution to the calibration of current transformers with the rated secondary currents of less than 1A. The paper presents a new, modified differential measurement method that enables the calibration of the current transformers with the rated secondary current of less than 1A using a standard current transformer with the rated secondary current of 5A.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-26
DOI
https://doi.org/10.1016/j.measen.2024.101428
Citations
2
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contribution to the calibration of current transformers with a rated secondary current of less than 1A

Slobodan Škundrić, Dragana Naumović-Vuković
2 citations
Measurement Sensors
Advanced Electrical Measurement Techniques
0.42
article

Contribution to the calibration of current transformers with a rated secondary current of less than 1A

Slobodan Škundrić, Dragana Naumović-Vuković
article en
2 citations

Abstract

Standardized values of current transformers with the rated secondary currents of 5 A and 1 A are defined according to the requirements of analog measuring and relay techniques that were typical for the technology of the last century. The development of microprocessor technics and technology as well as digitalization processes in transmission and distribution sectors of power industry requires rated secondary currents of current transformers of less than 1A. That implies different technical and technology difficulties in manufacturing such transformers as well as its accuracy testing. This paper is contribution to the calibration of current transformers with the rated secondary currents of less than 1A. The paper presents a new, modified differential measurement method that enables the calibration of the current transformers with the rated secondary current of less than 1A using a standard current transformer with the rated secondary current of 5A.

Measurement SensorsVol. 38
Univerzitet Union Nikola Tesla (RS)
Affordable and clean energy
Openalex Percentile: Top 36%
Advanced Electrical Measurement Techniques
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Contribution to the calibration of current transformers with a rated secondary current of less than 1A — Slobodan Škundrić, Dragana Naumović-Vuković · Measurement Sensors (2024) | TGRS Research Map | TGRS