Prospective Study of Dobutamine Stress Echocardiography in Comparison with 18F-fluorodeoxyglucose Positron Emission Tomography for Myocardial Viability in Ischemic Cardiomyopathy

Abstract Background: Myocardial viability is utilized in the decision-making process for suitability of revascularization in patients with coronary artery disease and depressed left ventricular (LV) function. Aims: The aim of this study was to compare the accuracy of dobutamine stress echocardiography (DSE) with the 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) for the identification of viable myocardium in patients with previous myocardial infarction and LV dysfunction. Settings and Design: This was a prospective observational study done at Nizam’s Institute of Medical Sciences. Materials and Methods: Patients with coronary artery disease with previous myocardial infarction with significant LV dysfunction were included in the study. Statistical Analysis: Categorical variables were presented in number and percentage (%), and continuous variables were presented as mean ± standard deviation. Student’s paired t -test was applied to test the difference between the outcomes of 18F-FDG PET and dobutamine stress echo. The statistical software SPSS 17.0 version was used in the analysis of the data. Results: In our study population, the mean LV ejection fraction was 35.1%. A total of 800 myocardial segments were evaluated with resting two-dimensional echocardiography examination, of which 250 (31.2%) were normal and 550 (68.8%) were abnormal segments. The dysfunctional 550 segments were further assessed with DSE followed by 18F-FDG PET. In our study, 453 segments were viable on 18F-FDG PET and 407 segments viable on DSE ( P = 0.001). Viability was detected by both modalities in 88.1% and discordance in 11.9% of segments. These results yielded a positive predictive value of 97.8% and negative predictive value of 61.1% of DSE. Conclusions: On considering 18F-FDG PET a gold standard for detection of viable myocardial segments, DSE has shown a sensitivity of 87.6% and specificity of 90.7%. Thus, DSE can be used as a good alternate to 18F-FDG PET where facility for FDG PET is not available. However, patients detected to have nonviable dysfunctional segments on DSE can be evaluated further with 18F-FDG PET for confirmation of viability.

Authors

Institutions

Publication Details

Journal
Journal of Indian College of Cardiology
Published
2024-10-01
DOI
https://doi.org/10.4103/jicc.jicc_70_24
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective Study of Dobutamine Stress Echocardiography in Comparison with 18F-fluorodeoxyglucose Positron Emission Tomography for Myocardial Viability in Ischemic Cardiomyopathy

Sama Rajashekhar, Aramalla Sunitha, Nuthalapati Rama Kumari
Journal of Indian College of Cardiology
Cardiac Imaging and Diagnostics
article

Prospective Study of Dobutamine Stress Echocardiography in Comparison with 18F-fluorodeoxyglucose Positron Emission Tomography for Myocardial Viability in Ischemic Cardiomyopathy

Sama Rajashekhar, Aramalla Sunitha, Nuthalapati Rama Kumari
article en

Abstract

Abstract Background: Myocardial viability is utilized in the decision-making process for suitability of revascularization in patients with coronary artery disease and depressed left ventricular (LV) function. Aims: The aim of this study was to compare the accuracy of dobutamine stress echocardiography (DSE) with the 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) for the identification of viable myocardium in patients with previous myocardial infarction and LV dysfunction. Settings and Design: This was a prospective observational study done at Nizam’s Institute of Medical Sciences. Materials and Methods: Patients with coronary artery disease with previous myocardial infarction with significant LV dysfunction were included in the study. Statistical Analysis: Categorical variables were presented in number and percentage (%), and continuous variables were presented as mean ± standard deviation. Student’s paired t -test was applied to test the difference between the outcomes of 18F-FDG PET and dobutamine stress echo. The statistical software SPSS 17.0 version was used in the analysis of the data. Results: In our study population, the mean LV ejection fraction was 35.1%. A total of 800 myocardial segments were evaluated with resting two-dimensional echocardiography examination, of which 250 (31.2%) were normal and 550 (68.8%) were abnormal segments. The dysfunctional 550 segments were further assessed with DSE followed by 18F-FDG PET. In our study, 453 segments were viable on 18F-FDG PET and 407 segments viable on DSE ( P = 0.001). Viability was detected by both modalities in 88.1% and discordance in 11.9% of segments. These results yielded a positive predictive value of 97.8% and negative predictive value of 61.1% of DSE. Conclusions: On considering 18F-FDG PET a gold standard for detection of viable myocardial segments, DSE has shown a sensitivity of 87.6% and specificity of 90.7%. Thus, DSE can be used as a good alternate to 18F-FDG PET where facility for FDG PET is not available. However, patients detected to have nonviable dysfunctional segments on DSE can be evaluated further with 18F-FDG PET for confirmation of viability.

Journal of Indian College of CardiologyVol. 14(4)
Nizam's Institute of Medical Sciences (IN)
Openalex Percentile: Top 59%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.