An Accuracy Study of Contact and Non-Contact Clinical Thermometers at Songklanagarind Hospital, Thailand

Objective: This study aimed to assess and validate the accuracy of contact clinical thermometers (CCTs), clinical digital thermometers (CDTs), temperature probes, and non-contact clinical infrared thermometers (NCCITs), which are commonly used at Songklanagarind Hospital.Material and Methods: The Medical Equipment and Maintenance Centre (MEMC) at Songklanagarind Hospital collected a total of 187 clinical thermometers, from various departments. This collection comprised of 45 temperature probes, 112 CDTs, and 30 infrared thermometers. All these thermometers underwent calibration at three distinct temperature points, via comparison with the secondary reference temperature standard (Pt100, SIKA). To assess the accuracy of the collected thermometers, an evaluation of the associated error and uncertainty was conducted. The maximum permissible errors (MPEs) were precisely defined as: ±0.2 °C and ±0.3 °C for CCT and ±0.5 °C for NCCIT.Results: The results revealed that all temperature probes, which represent 100% of the sample, demonstrated an average acceptable accuracy; determined by the average of the percentage of acceptable accuracy across three temperature calibration points, within the Maximum Permissible Error (MPE) range of ±0.2 °C. However, only 14% of the CDTs showed an average acceptable accuracy within the MPE of ±0.2 °C. Meanwhile, 51% of the CDTs met the MPE of ±0.3 °C. Additionally, 90% of the NCCIT demonstrated superior acceptable accuracy compared to the MPE of ±0.5 °C.Conclusion: This research emphasizes the significance of assessing the reliability and accuracy of clinical thermometers through calibration techniques; especially during the ongoing COVID-19 pandemic, which demands large-scale illness screening.

Authors

Institutions

Publication Details

Journal
Journal of Health Science and Medical Research
Published
2024-12-26
DOI
https://doi.org/10.31584/jhsmr.20241136
Primary Topic
Climate Change and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Accuracy Study of Contact and Non-Contact Clinical Thermometers at Songklanagarind Hospital, Thailand

Theera Leeudomwong, Tassanai Sanponpute, Mahdee Samae, Hanapong Kaewkhanitarak
Journal of Health Science and Medical Research
Climate Change and Health Impacts
article

An Accuracy Study of Contact and Non-Contact Clinical Thermometers at Songklanagarind Hospital, Thailand

Theera Leeudomwong, Tassanai Sanponpute, Mahdee Samae, Hanapong Kaewkhanitarak
article en

Abstract

Objective: This study aimed to assess and validate the accuracy of contact clinical thermometers (CCTs), clinical digital thermometers (CDTs), temperature probes, and non-contact clinical infrared thermometers (NCCITs), which are commonly used at Songklanagarind Hospital.Material and Methods: The Medical Equipment and Maintenance Centre (MEMC) at Songklanagarind Hospital collected a total of 187 clinical thermometers, from various departments. This collection comprised of 45 temperature probes, 112 CDTs, and 30 infrared thermometers. All these thermometers underwent calibration at three distinct temperature points, via comparison with the secondary reference temperature standard (Pt100, SIKA). To assess the accuracy of the collected thermometers, an evaluation of the associated error and uncertainty was conducted. The maximum permissible errors (MPEs) were precisely defined as: ±0.2 °C and ±0.3 °C for CCT and ±0.5 °C for NCCIT.Results: The results revealed that all temperature probes, which represent 100% of the sample, demonstrated an average acceptable accuracy; determined by the average of the percentage of acceptable accuracy across three temperature calibration points, within the Maximum Permissible Error (MPE) range of ±0.2 °C. However, only 14% of the CDTs showed an average acceptable accuracy within the MPE of ±0.2 °C. Meanwhile, 51% of the CDTs met the MPE of ±0.3 °C. Additionally, 90% of the NCCIT demonstrated superior acceptable accuracy compared to the MPE of ±0.5 °C.Conclusion: This research emphasizes the significance of assessing the reliability and accuracy of clinical thermometers through calibration techniques; especially during the ongoing COVID-19 pandemic, which demands large-scale illness screening.

Journal of Health Science and Medical Research
Prince of Songkla University (TH), Songklanagarind Hospital (TH), King Mongkut's University of Technology North Bangkok (TH)
National Science and Technology Development Agency, National Institute of Metrology, China, Office of National Higher Education Science Research and Innovation Policy Council
Good health and well-being
Openalex Percentile: Top 66%
Climate Change and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.