Phosphorous determination in nuclear reactor materials: dysprosium titanate, titanium dioxide and uranium oxide

Abstract A reliable analytical methodology is developed to determine phosphorus as phosphate in nuclear matrices viz uranium oxide, TiO 2 and dysprosium titanate by spectrophotometric molybdenum blue method. Refractory matrices (TiO 2 and dysprosium titanate) are dissolved employing microwave technique. Calibration is linear in the concentration range from 0.1 to 1.0 ppm of phosphorous with r 2 better than 0.9989. LOD obtained is 0.03 ppm. Method and instrumental RSD is 1 and 0.3%, respectively at 0.33 ppm level. Recovery of P at 0.33 ppm level is better than 95%. The developed method is validated by comparing results obtained by ion chromatography.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2024-12-26
DOI
https://doi.org/10.1007/s10967-024-09916-6
Primary Topic
Chemical Synthesis and Characterization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phosphorous determination in nuclear reactor materials: dysprosium titanate, titanium dioxide and uranium oxide

Poonam Verma, S. Johnson Jeyakumar, U. K. Thakur
Journal of Radioanalytical and Nuclear Chemistry
Chemical Synthesis and Characterization
article

Phosphorous determination in nuclear reactor materials: dysprosium titanate, titanium dioxide and uranium oxide

Poonam Verma, S. Johnson Jeyakumar, U. K. Thakur
article en

Abstract

Abstract A reliable analytical methodology is developed to determine phosphorus as phosphate in nuclear matrices viz uranium oxide, TiO 2 and dysprosium titanate by spectrophotometric molybdenum blue method. Refractory matrices (TiO 2 and dysprosium titanate) are dissolved employing microwave technique. Calibration is linear in the concentration range from 0.1 to 1.0 ppm of phosphorous with r 2 better than 0.9989. LOD obtained is 0.03 ppm. Method and instrumental RSD is 1 and 0.3%, respectively at 0.33 ppm level. Recovery of P at 0.33 ppm level is better than 95%. The developed method is validated by comparing results obtained by ion chromatography.

Journal of Radioanalytical and Nuclear ChemistryVol. 334(3)
Bhabha Atomic Research Centre (IN)
Bhabha Atomic Research Centre
Clean water and sanitation
Openalex Percentile: Top 70%
Chemical Synthesis and Characterization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.