Thermal Stability of Flexible Tanks When Affected by a Heat Flux from Upper Forest Fire

To extinguish large-scale and complex fires that are, for example, forest fires, a significant amount of fire-extinguishing agents and their long-distance feed using high-performance fire equipment, e.g. «Shkval», «Vodoley», and PANRC, are required. For these cases, flexible tanks are recommended for use as intermediate and storage tanks to prepare water solutions for fire-extinguishing agents. Multilayered composite polymer materials are used for their manufacture. When affected by a heat flux, thermal destruction occurs. According to the literary sources, the destruction of polymer materials of foreign manufacture starts at the temperature of 280–290 °С and reaches its maximum at the temperature of 410–420 °С. In the front of the upper forest fire, total heat fluxes (radiant and convective compounds) up to 120 kW/m2 are implemented, with a radiant heat flux reaching the value of 50 kW/m2. As the distance from the fire front increases, the heat flux decreases exponentially depending on the distance. An unsteady heat conductivity equation can describe the heating of materials used to manufacture a flexible tank for a multilayered structure in the form of a plate. Three schemes of multilayered structures have been considered; their relevant initial and boundary conditions have been set. A numerical solution for the heat conductivity equation using MathCad 2000 has been proposed. The obtained solution has been verified based on the text example from the US standard ASTMF 1930; the results of the calculation have been compared with the experimental data of laboratory tests in accordance with the GOST R 53264—19 methodology. The calculations comply with the experiment. Based on the heat flux data for an upper forest fire, the safe distance from the burn front to the flexible tank has been determined by calculations; it exceeds 20 m.

Authors

Publication Details

Journal
Occupational Safety in Industry
Published
2024-11-01
DOI
https://doi.org/10.24000/0409-2961-2024-11-15-21
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Stability of Flexible Tanks When Affected by a Heat Flux from Upper Forest Fire

E.Yu. Sushkina, N.P. Kopylov, V.I. Loginov, V.N. Nelyubov
Occupational Safety in Industry
Combustion and Detonation Processes
article

Thermal Stability of Flexible Tanks When Affected by a Heat Flux from Upper Forest Fire

E.Yu. Sushkina, N.P. Kopylov, V.I. Loginov, V.N. Nelyubov
article en

Abstract

To extinguish large-scale and complex fires that are, for example, forest fires, a significant amount of fire-extinguishing agents and their long-distance feed using high-performance fire equipment, e.g. «Shkval», «Vodoley», and PANRC, are required. For these cases, flexible tanks are recommended for use as intermediate and storage tanks to prepare water solutions for fire-extinguishing agents. Multilayered composite polymer materials are used for their manufacture. When affected by a heat flux, thermal destruction occurs. According to the literary sources, the destruction of polymer materials of foreign manufacture starts at the temperature of 280–290 °С and reaches its maximum at the temperature of 410–420 °С. In the front of the upper forest fire, total heat fluxes (radiant and convective compounds) up to 120 kW/m2 are implemented, with a radiant heat flux reaching the value of 50 kW/m2. As the distance from the fire front increases, the heat flux decreases exponentially depending on the distance. An unsteady heat conductivity equation can describe the heating of materials used to manufacture a flexible tank for a multilayered structure in the form of a plate. Three schemes of multilayered structures have been considered; their relevant initial and boundary conditions have been set. A numerical solution for the heat conductivity equation using MathCad 2000 has been proposed. The obtained solution has been verified based on the text example from the US standard ASTMF 1930; the results of the calculation have been compared with the experimental data of laboratory tests in accordance with the GOST R 53264—19 methodology. The calculations comply with the experiment. Based on the heat flux data for an upper forest fire, the safe distance from the burn front to the flexible tank has been determined by calculations; it exceeds 20 m.

Occupational Safety in Industry(11)
Openalex Percentile: Top 59%
Combustion and Detonation Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.