Semiconductive Coordination Polymer with Multi‐Channel Charge Transfer for High‐Performance Direct X‐ray Detection

Coordination polymers (CPs) are promising for direct X-ray detection and imaging owing to higher designability and outstanding stability, however, it remains a challenge to achieve highly X-ray detection performance, particularly both high sensitivity and low detection limit at the same operating voltage. Herein, we construct a new conjugated CP {[Co(BPTTz)(DIPA)] ⋅ DMA}<sub>n</sub> (1, BPTTz=2,5-bis(pyridine-4-yl)thiazolo[5,4-d]thiazole, H<sub>2</sub>DIPA=2,5-diiodoterephthalic acid, DMA=N, N'-dimethylacetamide), with multi-channel charge transfer by regulating the linker mediated electronic-state, which reduces carrier losses resulting from recombination or quenching, enhances the efficiency of charge separation and transfer, thus further optimizes X-ray detection performance. The semiconductor prepared based on this strategy achieves record values including the highest mobility-lifetime product (μτ, 8.05×10<sup>-3</sup> cm<sup>2</sup> V<sup>-1</sup>) and the lowest detectable X-ray dose rate (128 nGy<sub>air</sub> S<sup>-1</sup>, 35 V) among CP-based direct radiation detectors, as well as a high sensitivity (172 μC Gy<sub>air</sub> <sup>-1</sup> cm<sup>-2</sup>, 35 V) at the same operating voltage. This detector shows excellent long-time air stability under ambient conditions for over three months and operational stability. These findings demonstrate a rational structural design method to enhance the photoelectronic efficiency and stability of semiconductive CPs.

Authors

Institutions

Publication Details

Journal
Angewandte Chemie International Edition
Published
2024-12-25
DOI
https://doi.org/10.1002/anie.202419266
Citations
9
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
2.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Semiconductive Coordination Polymer with Multi‐Channel Charge Transfer for High‐Performance Direct X‐ray Detection

Jihong Yu, Bolun Wang
9 citations
Angewandte Chemie International Edition
Analytical Chemistry and Sensors
2.60
article

Semiconductive Coordination Polymer with Multi‐Channel Charge Transfer for High‐Performance Direct X‐ray Detection

Jihong Yu, Bolun Wang
article en
9 citations

Abstract

Coordination polymers (CPs) are promising for direct X-ray detection and imaging owing to higher designability and outstanding stability, however, it remains a challenge to achieve highly X-ray detection performance, particularly both high sensitivity and low detection limit at the same operating voltage. Herein, we construct a new conjugated CP {[Co(BPTTz)(DIPA)] ⋅ DMA}<sub>n</sub> (1, BPTTz=2,5-bis(pyridine-4-yl)thiazolo[5,4-d]thiazole, H<sub>2</sub>DIPA=2,5-diiodoterephthalic acid, DMA=N, N'-dimethylacetamide), with multi-channel charge transfer by regulating the linker mediated electronic-state, which reduces carrier losses resulting from recombination or quenching, enhances the efficiency of charge separation and transfer, thus further optimizes X-ray detection performance. The semiconductor prepared based on this strategy achieves record values including the highest mobility-lifetime product (μτ, 8.05×10<sup>-3</sup> cm<sup>2</sup> V<sup>-1</sup>) and the lowest detectable X-ray dose rate (128 nGy<sub>air</sub> S<sup>-1</sup>, 35 V) among CP-based direct radiation detectors, as well as a high sensitivity (172 μC Gy<sub>air</sub> <sup>-1</sup> cm<sup>-2</sup>, 35 V) at the same operating voltage. This detector shows excellent long-time air stability under ambient conditions for over three months and operational stability. These findings demonstrate a rational structural design method to enhance the photoelectronic efficiency and stability of semiconductive CPs.

Angewandte Chemie International EditionVol. 64(7)
City University of Hong Kong (HK), Jilin University (CN), Chinese Academy of Sciences (CN), Fujian Institute of Research on the Structure of Matter (CN), Jilin International Studies University (CN), State Key Laboratory of Inorganic Synthesis and Preparative Chemistry
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Overseas Expertise Introduction Center for Discipline Innovation of Food Nutrition and Human Health (111 Center)
Affordable and clean energy
Openalex Percentile: Top 10%
Analytical Chemistry and Sensors
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.