Portable robot for needle insertion assistance to femoral artery

Femoral artery access is a common and critical procedure for various cardiovascular interventions. Although it is a time critical operation, accessing the Common Femoral Artery (CFA) typically requires expertise found in specialized medical settings. The necessity for specialized personnel or transport to equipped facilities can lead to delays, potentially exacerbating patient outcomes. To address this challenge, a portable and cost-effective robotic device that autonomously localizes a CFA and precisely positions a needle guide is developed. Through the needle guide, needle can be quickly and accurately inserted into the artery even by non-specialist physicians. Different from the conventional B-mode ultrasound guided procedure, the proposed robotic solution utilizes a Doppler transducer for detecting the arterial location and employs a single M-mode transducer for depth measurement. A series of experiments are designed and conducted to validate the system’s feasibility, achieving high accuracy within 2 mm, rapid processing within 1.5 min, and a 100% success rate, thus proving the system’s efficacy. These results convince us for further refinement of the system and support its evaluation in animal studies.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10802084
Citations
1
Primary Topic
Cardiac and Coronary Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable robot for needle insertion assistance to femoral artery

M. Jensen, Hugh Frost, Siheon An, Zhuoqi Cheng et al.
1 citations
Cardiac and Coronary Surgery Techniques
0.57
article

Portable robot for needle insertion assistance to femoral artery

M. Jensen, Hugh Frost, Siheon An, Zhuoqi Cheng, Kasper Jørgensen, Thiusius Rajeeth Savarimuthu, Bence Mány, Richard Thulstrup, Olof Huldt
article en
1 citations

Abstract

Femoral artery access is a common and critical procedure for various cardiovascular interventions. Although it is a time critical operation, accessing the Common Femoral Artery (CFA) typically requires expertise found in specialized medical settings. The necessity for specialized personnel or transport to equipped facilities can lead to delays, potentially exacerbating patient outcomes. To address this challenge, a portable and cost-effective robotic device that autonomously localizes a CFA and precisely positions a needle guide is developed. Through the needle guide, needle can be quickly and accurately inserted into the artery even by non-specialist physicians. Different from the conventional B-mode ultrasound guided procedure, the proposed robotic solution utilizes a Doppler transducer for detecting the arterial location and employs a single M-mode transducer for depth measurement. A series of experiments are designed and conducted to validate the system’s feasibility, achieving high accuracy within 2 mm, rapid processing within 1.5 min, and a 100% success rate, thus proving the system’s efficacy. These results convince us for further refinement of the system and support its evaluation in animal studies.

Chonnam National University (KR)
Innovation Fund
Openalex Percentile: Top 26%
Cardiac and Coronary Surgery Techniques
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.