DESectBot: Design and Validation of a Novel Two-Segment Decoupled Continuum Robotic System for Endoscopic Submucosal Dissection

Endoscopic Submucosal Dissection (ESD) is a minimally invasive procedure designed to remove precancerous and cancerous lesions from the gastrointestinal (GI) tract. Given the GI tract’s tortuous and narrow shape, along with the need for varied movements during dissection, this requires highly flexible and compact instruments, making flexible continuum robots suitable candidates. In this paper, we propose a novel two-segment continuum robot system named DESectBot, featuring a diameter of 5.5 mm and a total length of the active bending module of 48 mm, while the robot’s total length exceeds 1 m. We designed a novel joint combination structure called the spatial cross-curved disk skeleton for the robot, which addresses the mechanical coupling problem between flexible robot actuators. The DESectBot boasts six degrees of freedom, and its kinematic modeling has been derived and utilized in the closed-loop control of the DESectBot. The validation of the DESectBot was conducted through a two-stage test: first, the decoupling performance of the DESectBot was validated. The results show that when one active bending segment bends, the other segment remains almost uninfluenced, with a maximum variation of 1.15 degrees, demonstrating the robot’s effective decoupling capability. Secondly, the accuracy of DESectBot was validated through trajectory-following experiments. The results reveal that the average tracking error for both trajectories is less than 2 mm, and the maximum tracking error is below 2.5 mm. Taking marking, one of the ESD procedures with a 5mm tolerance, as an example, the DESectBot has the potential to be utilized for ESD procedure.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10802473
Citations
3
Primary Topic
Gastric Cancer Management and Outcomes
Type
article
Field-Weighted Citation Impact
1.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DESectBot: Design and Validation of a Novel Two-Segment Decoupled Continuum Robotic System for Endoscopic Submucosal Dissection

Peng Qi, Zixi Chen, Di Wu, Cesare Stefanini et al.
3 citations
Gastric Cancer Management and Outcomes
1.26
article

DESectBot: Design and Validation of a Novel Two-Segment Decoupled Continuum Robotic System for Endoscopic Submucosal Dissection

Peng Qi, Zixi Chen, Di Wu, Cesare Stefanini, Yuancheng Shao, Wenjie Liu, Ling Li, Yao Zhang, Yuqiao Chen
article en
3 citations

Abstract

Endoscopic Submucosal Dissection (ESD) is a minimally invasive procedure designed to remove precancerous and cancerous lesions from the gastrointestinal (GI) tract. Given the GI tract’s tortuous and narrow shape, along with the need for varied movements during dissection, this requires highly flexible and compact instruments, making flexible continuum robots suitable candidates. In this paper, we propose a novel two-segment continuum robot system named DESectBot, featuring a diameter of 5.5 mm and a total length of the active bending module of 48 mm, while the robot’s total length exceeds 1 m. We designed a novel joint combination structure called the spatial cross-curved disk skeleton for the robot, which addresses the mechanical coupling problem between flexible robot actuators. The DESectBot boasts six degrees of freedom, and its kinematic modeling has been derived and utilized in the closed-loop control of the DESectBot. The validation of the DESectBot was conducted through a two-stage test: first, the decoupling performance of the DESectBot was validated. The results show that when one active bending segment bends, the other segment remains almost uninfluenced, with a maximum variation of 1.15 degrees, demonstrating the robot’s effective decoupling capability. Secondly, the accuracy of DESectBot was validated through trajectory-following experiments. The results reveal that the average tracking error for both trajectories is less than 2 mm, and the maximum tracking error is below 2.5 mm. Taking marking, one of the ESD procedures with a 5mm tolerance, as an example, the DESectBot has the potential to be utilized for ESD procedure.

Tongji University (CN), Sehenstar Energy Technology (China) (CN), Center for Micro-BioRobotics (IT), Zhuhai Institute of Advanced Technology (CN), KU Leuven (BE)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 17%
Gastric Cancer Management and Outcomes
1.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.