Continuum Robot Shape Estimation Using Magnetic Ball Chains

Shape sensing of medical continuum robots is important both for closed-loop control as well as for enabling the clinician to visualize the robot inside the body. There is a need for inexpensive, but accurate shape sensing technologies. This paper proposes the use of magnetic ball chains as a means of generating shape-specific magnetic fields that can be detected by an external array of Hall effect sensors. Such a ball chain, encased in a flexible polymer sleeve, could be inserted inside the lumen of any continuum robot to provide real-time shape feedback. The sleeve could be removed, as needed, during the procedure to enable use of the entire lumen. To investigate this approach, a shape-sensing model for a steerable catheter tip is derived and an observability and sensitivity analysis are presented. Experiments show maximum estimation errors of 7.1% and mean of 2.9% of the tip position with respect to total length.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10801952
Citations
5
Primary Topic
Robotics and Sensor-Based Localization
Type
article
Field-Weighted Citation Impact
6.49

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuum Robot Shape Estimation Using Magnetic Ball Chains

Pierre E. Dupont, Abdulhamit Donder, Giovanni Pittiglio
5 citations
Robotics and Sensor-Based Localization
6.49
article

Continuum Robot Shape Estimation Using Magnetic Ball Chains

Pierre E. Dupont, Abdulhamit Donder, Giovanni Pittiglio
article en
5 citations

Abstract

Shape sensing of medical continuum robots is important both for closed-loop control as well as for enabling the clinician to visualize the robot inside the body. There is a need for inexpensive, but accurate shape sensing technologies. This paper proposes the use of magnetic ball chains as a means of generating shape-specific magnetic fields that can be detected by an external array of Hall effect sensors. Such a ball chain, encased in a flexible polymer sleeve, could be inserted inside the lumen of any continuum robot to provide real-time shape feedback. The sleeve could be removed, as needed, during the procedure to enable use of the entire lumen. To investigate this approach, a shape-sensing model for a steerable catheter tip is derived and an observability and sensitivity analysis are presented. Experiments show maximum estimation errors of 7.1% and mean of 2.9% of the tip position with respect to total length.

Worcester Polytechnic Institute (US), Boston Children's Hospital (US), Harvard University (US)
National Institutes of Health
Openalex Percentile: Top 4%
Robotics and Sensor-Based Localization
6.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.