Design of a Reconfigurable Sensor Array for Localization of Magnetic Capsule Endoscope

Magnetic capsule endoscope (MCE) has been well used in clinical diagnosis. However, localization for MCE was still lacking in clinical scenarios. In this study, we developed a reconfigurable magnetic localization system (MLS) and a localization algorithm for MCE in clinical scenarios. The magnetic sensor array consists of six sensor boards. Configuration of the array, which is defined as homogeneous transformation matrices between these boards, can be adjusted based on anatomical structures to adapt to different patient sizes. The proposed localization algorithm includes initial value estimation and optimization. The initial value estimation method is based on an automatic sensor selection process, which can provide an effective iterative initial value for the optimization algorithm. In vitro experiments with commercial magnetic capsules were conducted in static and dynamic manners. The average position error in the static localization experiment was 1.2 mm with a standard deviation of 0.6 mm. The average position error in the dynamic tracking experiment was 2.4 mm with a standard deviation of 2.0 mm. Results showed that the proposed method can locate the capsule robot effectively, making it a valuable addition to noninvasive gastrointestinal diagnosis and treatment.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2024-12-25
DOI
https://doi.org/10.1109/tim.2024.3522675
Citations
7
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
3.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a Reconfigurable Sensor Array for Localization of Magnetic Capsule Endoscope

Shuang Song, J.-J. Su, Hongxi Liu
7 citations
IEEE Transactions on Instrumentation and Measurement
Gastrointestinal Bleeding Diagnosis and Treatment
3.25
article

Design of a Reconfigurable Sensor Array for Localization of Magnetic Capsule Endoscope

Shuang Song, J.-J. Su, Hongxi Liu
article en
7 citations

Abstract

Magnetic capsule endoscope (MCE) has been well used in clinical diagnosis. However, localization for MCE was still lacking in clinical scenarios. In this study, we developed a reconfigurable magnetic localization system (MLS) and a localization algorithm for MCE in clinical scenarios. The magnetic sensor array consists of six sensor boards. Configuration of the array, which is defined as homogeneous transformation matrices between these boards, can be adjusted based on anatomical structures to adapt to different patient sizes. The proposed localization algorithm includes initial value estimation and optimization. The initial value estimation method is based on an automatic sensor selection process, which can provide an effective iterative initial value for the optimization algorithm. In vitro experiments with commercial magnetic capsules were conducted in static and dynamic manners. The average position error in the static localization experiment was 1.2 mm with a standard deviation of 0.6 mm. The average position error in the dynamic tracking experiment was 2.4 mm with a standard deviation of 2.0 mm. Results showed that the proposed method can locate the capsule robot effectively, making it a valuable addition to noninvasive gastrointestinal diagnosis and treatment.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Harbin Institute of Technology (CN), Qilu Hospital of Shandong University (CN)
National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 8%
Gastrointestinal Bleeding Diagnosis and Treatment
3.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of a Reconfigurable Sensor Array for Localization of Magnetic Capsule Endoscope — Shuang Song, J.-J. Su, et al. · IEEE Transactions on Instrumentation and Measurement (2024) | TGRS Research Map | TGRS