Efficient Extrinsic Self-Calibration of Multiple IMUs using Measurement Subset Selection

This paper addresses the problem of choosing a sparse subset of measurements for quick calibration parameter estimation. A standard solution to this is selecting a measurement only if its utility—the difference between posterior (with the measurement) and prior information (without the measurement)—exceeds some threshold. Theoretically, utility, a function of the parameter estimate, should be evaluated at the estimate obtained with all measurements selected so far, hence necessitating a recalibration with each new measurement. However, we hypothesize that utility is insensitive to changes in the parameter estimate for many systems of interest, suggesting that evaluating utility at some initial parameter guess would yield equivalent results in practice. We provide evidence supporting this hypothesis for extrinsic calibration of multiple inertial measurement units (IMUs), showing the reduction in calibration time by two orders of magnitude by forgoing recalibration for each measurement.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10802604
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient Extrinsic Self-Calibration of Multiple IMUs using Measurement Subset Selection

David Hanley, Jongwon Lee, Timothy Bretl
Fault Detection and Control Systems
article

Efficient Extrinsic Self-Calibration of Multiple IMUs using Measurement Subset Selection

David Hanley, Jongwon Lee, Timothy Bretl
article en

Abstract

This paper addresses the problem of choosing a sparse subset of measurements for quick calibration parameter estimation. A standard solution to this is selecting a measurement only if its utility—the difference between posterior (with the measurement) and prior information (without the measurement)—exceeds some threshold. Theoretically, utility, a function of the parameter estimate, should be evaluated at the estimate obtained with all measurements selected so far, hence necessitating a recalibration with each new measurement. However, we hypothesize that utility is insensitive to changes in the parameter estimate for many systems of interest, suggesting that evaluating utility at some initial parameter guess would yield equivalent results in practice. We provide evidence supporting this hypothesis for extrinsic calibration of multiple inertial measurement units (IMUs), showing the reduction in calibration time by two orders of magnitude by forgoing recalibration for each measurement.

University of Illinois Urbana-Champaign (US), Centre for Inflammation Research (GB), University of Edinburgh (GB)
Openalex Percentile: Top 71%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Efficient Extrinsic Self-Calibration of Multiple IMUs using Measurement Subset Selection — David Hanley, Jongwon Lee, et al. · (2024) | TGRS Research Map | TGRS