Contingency Analysis of an IEEE 9 Bus System Considering Optimal Location of UPFC by Artificial Bee Colony (ABC) Algorithm

Contingency analysis is essential for protecting the security of the power system. It is the examination of a power system when one or more of its components fails. A power system may experience contingencies as a result of internal component failures or as a result of external causes like equipment overload. Multiple issues, such as voltage instability, overloads, equipment damage, and power supply interruptions, can arise as a result of them. In power systems, a lot of Flexible Alternating Current Transmission System (FACTS) devices are used to minimize these issues. They are also used in the transmission of power to increase transfer capacity and lower transmission line losses. Unified Power Flow Controller (UPFC) is a flexible FACTS device that can minimize active and reactive power loss and improve bus voltage separately or all at once; however, it is crucial to place the UPFC in the most advantageous position in the power system to achieve this functionality. In our work, analysis of contingency has been performed in an IEEE-9 bus system. Outages of generators, transformers, and transmission lines have been observed. Load flow analysis has been done before and after each outage. Based on performance index, the outage of each component has been ranked. The impact of each outage on the transmission lines is measured using another parameter called severity index. The most severe outages violate line MVA and bus voltage limits. Besides, to get the optimal location of the Unified Power Flow Controller (UPFC), Artificial Bee Colony (ABC) Algorithm is proposed considering the most significant outages. The results show that placing UPFC devices in the bus system has reduced active power loss by 13%, and reactive power loss is reduced by 13.47 %. Besides real and reactive power minimization, the voltage profile is also improved after placing UPFC in the bus system.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/peeiacon63629.2024.10800638
Citations
1
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contingency Analysis of an IEEE 9 Bus System Considering Optimal Location of UPFC by Artificial Bee Colony (ABC) Algorithm

Md. Manjurul Gani, Kaniz Fatema, Durra Tarannum, Mohammed Shale Jounaed Monir
1 citations
Smart Grid Security and Resilience
0.33
article

Contingency Analysis of an IEEE 9 Bus System Considering Optimal Location of UPFC by Artificial Bee Colony (ABC) Algorithm

Md. Manjurul Gani, Kaniz Fatema, Durra Tarannum, Mohammed Shale Jounaed Monir
article en
1 citations

Abstract

Contingency analysis is essential for protecting the security of the power system. It is the examination of a power system when one or more of its components fails. A power system may experience contingencies as a result of internal component failures or as a result of external causes like equipment overload. Multiple issues, such as voltage instability, overloads, equipment damage, and power supply interruptions, can arise as a result of them. In power systems, a lot of Flexible Alternating Current Transmission System (FACTS) devices are used to minimize these issues. They are also used in the transmission of power to increase transfer capacity and lower transmission line losses. Unified Power Flow Controller (UPFC) is a flexible FACTS device that can minimize active and reactive power loss and improve bus voltage separately or all at once; however, it is crucial to place the UPFC in the most advantageous position in the power system to achieve this functionality. In our work, analysis of contingency has been performed in an IEEE-9 bus system. Outages of generators, transformers, and transmission lines have been observed. Load flow analysis has been done before and after each outage. Based on performance index, the outage of each component has been ranked. The impact of each outage on the transmission lines is measured using another parameter called severity index. The most severe outages violate line MVA and bus voltage limits. Besides, to get the optimal location of the Unified Power Flow Controller (UPFC), Artificial Bee Colony (ABC) Algorithm is proposed considering the most significant outages. The results show that placing UPFC devices in the bus system has reduced active power loss by 13%, and reactive power loss is reduced by 13.47 %. Besides real and reactive power minimization, the voltage profile is also improved after placing UPFC in the bus system.

Chittagong University of Engineering & Technology (BD)
Openalex Percentile: Top 38%
Smart Grid Security and Resilience
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.