Analysing Harmonic Resonance Behaviour of a Grid-Connected PV Plant

The incorporation of inverter-based resources (IBR) into the power grid has led to new power quality challenges, including higher-order harmonics (supraharmonics), frequent transient voltages, power oscillations, etc. The supra-harmonics could damage assets that were originally designed to operate under power frequency. Furthermore, power quality standards have not yet set limits for higher-order harmonics. Moreover, the configuration of IBRs may result in higher-order resonance, potentially exacerbating these harmonic levels. Hence, in this paper, the effect of harmonics due to resonance characteristics of a grid-connected PV plant has been studied through simulations to understand the factors that affect forming resonance conditions at supra-harmonics levels. This study was extended by incorporating measured harmonic currents to understand the level of harmonic voltages that could appear at the transformer terminal under these resonance conditions. The results show the significance of considering the higher-order harmonics in Voltage Total Harmonic Distortion (Vthd) calculations, where existing limits by the standards could be violated at these resonance conditions.

Authors

Institutions

Publication Details

Published
2024-11-20
DOI
https://doi.org/10.1109/aupec62273.2024.10807515
Citations
3
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysing Harmonic Resonance Behaviour of a Grid-Connected PV Plant

Hui Ma, A. S. K. Abeysekara, Chandima Ekanayake
3 citations
Power Systems and Renewable Energy
0.51
article

Analysing Harmonic Resonance Behaviour of a Grid-Connected PV Plant

Hui Ma, A. S. K. Abeysekara, Chandima Ekanayake
article en
3 citations

Abstract

The incorporation of inverter-based resources (IBR) into the power grid has led to new power quality challenges, including higher-order harmonics (supraharmonics), frequent transient voltages, power oscillations, etc. The supra-harmonics could damage assets that were originally designed to operate under power frequency. Furthermore, power quality standards have not yet set limits for higher-order harmonics. Moreover, the configuration of IBRs may result in higher-order resonance, potentially exacerbating these harmonic levels. Hence, in this paper, the effect of harmonics due to resonance characteristics of a grid-connected PV plant has been studied through simulations to understand the factors that affect forming resonance conditions at supra-harmonics levels. This study was extended by incorporating measured harmonic currents to understand the level of harmonic voltages that could appear at the transformer terminal under these resonance conditions. The results show the significance of considering the higher-order harmonics in Voltage Total Harmonic Distortion (Vthd) calculations, where existing limits by the standards could be violated at these resonance conditions.

The University of Queensland (AU)
Openalex Percentile: Top 28%
Power Systems and Renewable Energy
0.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.