Design Improvements to the Float Upper-Limb Exoskeleton Better Mimics the Glenohumeral Complex Kinematics

The shoulder glenohumeral complex stands out as one of the most complex structures within the human body. Designing a system that can effectively interface with it poses a significant challenge for researchers. In this study, we propose a methodology based on evaluating various metrics to assess the performance of new kinematic solutions for mimicking the glenohumeral complex. The proposed method is demonstrated on an existing design (Float) of an upper-limb exoskeleton. The results show a successful expansion of the reachable workspace and enhancement of the shoulder internal-external rotation. The improvements ensure the necessary range-of-motion for the patient’s natural use of the exoskeleton. Specifically, the existing Eulerian wrist architecture is replaced with a 3-degree-of-freedom RPY wrist to better resemble the glenohumeral shoulder joint complex. This study also explores the trade-offs between these enhancements and the desired system manipulability.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10802633
Citations
1
Primary Topic
Shoulder and Clavicle Injuries
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design Improvements to the Float Upper-Limb Exoskeleton Better Mimics the Glenohumeral Complex Kinematics

Matteo Laffranchi, Stefano Buccelli, Federico Tessari, Luca De Guglielmo et al.
1 citations
Shoulder and Clavicle Injuries
0.39
article

Design Improvements to the Float Upper-Limb Exoskeleton Better Mimics the Glenohumeral Complex Kinematics

Matteo Laffranchi, Stefano Buccelli, Federico Tessari, Luca De Guglielmo, Giulia Bodo, Gianluca Capitta
article en
1 citations

Abstract

The shoulder glenohumeral complex stands out as one of the most complex structures within the human body. Designing a system that can effectively interface with it poses a significant challenge for researchers. In this study, we propose a methodology based on evaluating various metrics to assess the performance of new kinematic solutions for mimicking the glenohumeral complex. The proposed method is demonstrated on an existing design (Float) of an upper-limb exoskeleton. The results show a successful expansion of the reachable workspace and enhancement of the shoulder internal-external rotation. The improvements ensure the necessary range-of-motion for the patient’s natural use of the exoskeleton. Specifically, the existing Eulerian wrist architecture is replaced with a 3-degree-of-freedom RPY wrist to better resemble the glenohumeral shoulder joint complex. This study also explores the trade-offs between these enhancements and the desired system manipulability.

Politecnico di Torino (IT), Italian Institute of Technology (IT), Massachusetts Institute of Technology (US)
Openalex Percentile: Top 31%
Shoulder and Clavicle Injuries
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design Improvements to the Float Upper-Limb Exoskeleton Better Mimics the Glenohumeral Complex Kinematics — Matteo Laffranchi, Stefano Buccelli, et al. · (2024) | TGRS Research Map | TGRS