Thermal Ablation Therapy Control with Tissue Necrosis-driven Temperature Feedback Enabled by Neural State Space Model with Extended Kalman Filter

Thermal ablation therapy is a major minimally invasive treatment. One of the challenges is that the targeted region and therapeutic progression are often invisible to clinicians, requiring feedback provided in numerical information or imaging. Several emerging imaging modalities offer visualization of the ablation-induced necrosis formation; however, relying solely on necrosis monitoring can result in tissue overheating and endangering patients. Some of the necrosis monitoring modalities are known for their capabilities in temperature sensing, but the principles on which they are based have several limitations, such as sensitivity to the tissue motion and their environment. In this study, we propose a necrosis progression-based temperature estimation technique as an added safety feature for avoiding overheating. This model-based method does not require additional sensing hardware. It is designed to work as an independent estimator or a complimentary estimation component with other thermometers for improved robustness. For this objective, the Neural State Space model is used to approximate the ablation therapy, whose theoretical models involve nonlinear partial differential equations. Then, the Extended Kalman Filter is designed based on the model. The simulation study shows the estimation module robustly estimates the tissue temperature under several types of noise. The maximum estimation error observed before terminating ablation was around 1 °C, and the desired safety feature was successfully demonstrated. The estimator is expected to be used in a variety of necrosis monitoring modalities to guarantee more precise and safer treatment. More ambitiously, the architecture with the Neural State Space model and Extended Kalman Filter is generalizable to other medical/biological procedures involving nonlinear and patient/environment-specific physics and even to procedures having no reliable theoretical models.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10801769
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Ablation Therapy Control with Tissue Necrosis-driven Temperature Feedback Enabled by Neural State Space Model with Extended Kalman Filter

Ryo Murakami, Satoshi Mori, Haichong K. Zhang
1 citations
Non-Invasive Vital Sign Monitoring
0.18
article

Thermal Ablation Therapy Control with Tissue Necrosis-driven Temperature Feedback Enabled by Neural State Space Model with Extended Kalman Filter

Ryo Murakami, Satoshi Mori, Haichong K. Zhang
article en
1 citations

Abstract

Thermal ablation therapy is a major minimally invasive treatment. One of the challenges is that the targeted region and therapeutic progression are often invisible to clinicians, requiring feedback provided in numerical information or imaging. Several emerging imaging modalities offer visualization of the ablation-induced necrosis formation; however, relying solely on necrosis monitoring can result in tissue overheating and endangering patients. Some of the necrosis monitoring modalities are known for their capabilities in temperature sensing, but the principles on which they are based have several limitations, such as sensitivity to the tissue motion and their environment. In this study, we propose a necrosis progression-based temperature estimation technique as an added safety feature for avoiding overheating. This model-based method does not require additional sensing hardware. It is designed to work as an independent estimator or a complimentary estimation component with other thermometers for improved robustness. For this objective, the Neural State Space model is used to approximate the ablation therapy, whose theoretical models involve nonlinear partial differential equations. Then, the Extended Kalman Filter is designed based on the model. The simulation study shows the estimation module robustly estimates the tissue temperature under several types of noise. The maximum estimation error observed before terminating ablation was around 1 °C, and the desired safety feature was successfully demonstrated. The estimator is expected to be used in a variety of necrosis monitoring modalities to guarantee more precise and safer treatment. More ambitiously, the architecture with the Neural State Space model and Extended Kalman Filter is generalizable to other medical/biological procedures involving nonlinear and patient/environment-specific physics and even to procedures having no reliable theoretical models.

Vol. 2024
Worcester Polytechnic Institute (US)
National Institutes of Health
Affordable and clean energy
Openalex Percentile: Top 49%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.