Development of a Low Pressure Pouch Sensor for Force Measurement in Colonoscopy Procedures

This paper presents a novel pneumatic pouch sensor, designed to mount on a colonoscope, that can effectively estimate the contact forces with the environment. The pouch sensor was designed to maximize the sensing range, and it was fabricated using a 2D laser welding technique from our track record. A flow compensation (FC) algorithm was introduced to improve the accuracy of the sensor in the presence of static load. The proposed system can reliably measure external forces up to 9.5 N with high repeatability. The system allows discriminating between different levels of force which are typically associated with increasing patient discomfort in colonoscopy: low (0-4 N), medium (4-6 N), and high (>6 N). This system achieves over 80% accuracy in comparison to the ground truth under steady state conditions (P ≤ 0.05) and maintains over 68% accuracy in dynamic scenarios.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10802184
Citations
2
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.69

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Low Pressure Pouch Sensor for Force Measurement in Colonoscopy Procedures

Mark Runciman, Ferdinando Rodriguez y Baena, Korn Borvorntanajanya, Jabed F Ahmed et al.
2 citations
Medical Device Sterilization and Disinfection
0.69
article

Development of a Low Pressure Pouch Sensor for Force Measurement in Colonoscopy Procedures

Mark Runciman, Ferdinando Rodriguez y Baena, Korn Borvorntanajanya, Jabed F Ahmed, Nisha Patel, Enrico Franco
article en
2 citations

Abstract

This paper presents a novel pneumatic pouch sensor, designed to mount on a colonoscope, that can effectively estimate the contact forces with the environment. The pouch sensor was designed to maximize the sensing range, and it was fabricated using a 2D laser welding technique from our track record. A flow compensation (FC) algorithm was introduced to improve the accuracy of the sensor in the presence of static load. The proposed system can reliably measure external forces up to 9.5 N with high repeatability. The system allows discriminating between different levels of force which are typically associated with increasing patient discomfort in colonoscopy: low (0-4 N), medium (4-6 N), and high (>6 N). This system achieves over 80% accuracy in comparison to the ground truth under steady state conditions (P ≤ 0.05) and maintains over 68% accuracy in dynamic scenarios.

Imperial College London (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 27%
Medical Device Sterilization and Disinfection
0.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a Low Pressure Pouch Sensor for Force Measurement in Colonoscopy Procedures — Mark Runciman, Ferdinando Rodriguez y Baena, et al. · (2024) | TGRS Research Map | TGRS