An Optical Interferometer-based Force Sensor System for Enhancing Precision in Epidural Injection Procedure

In minimally invasive pain management procedures, precise needle positioning is paramount for effective treatment and patient safety. Traditional techniques like the loss-of-resistance (LOR) method may be insufficient, especially in patients with narrowed epidural spaces. The use of imaging tools such as C-arms carries risks due to radiation exposure for medical professionals. A new system for detecting the epidural space based on optical interferometry is proposed to tackle this issue. Prior research has focused on force measurement systems to identify tissue puncture or rupture. Although mechanical sensors have been utilized, they add bulk and complexity to systems. Optical sensors like Fiber Bragg grating (FBG) and Fabry-Pérot interferometer (FPI) offer stable, high-resolution measurements suitable for complex biological tissues. This study aims to develop a sensor and needle system for epidural injections, incorporating quantitative metrics for validation. An optical interferometer-based force measurement sensor was integrated into a commercial epidural needle, and calibration was performed to establish a correlation between system output and actual force. The system employs a graphical user interface (GUI) to identify puncture points based on abrupt force decreases. A user study involving interventionalists assessed the system’s performance by measuring invasive depth and success rates. The user study demonstrated that the proposed sensorized system could detect the puncture with an average success rate of 72.63 %. This study represents a significant advancement toward safer and more precise epidural procedures, addressing critical clinical considerations for practical applications.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/iros58592.2024.10802501
Citations
2
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Optical Interferometer-based Force Sensor System for Enhancing Precision in Epidural Injection Procedure

Jintaek Im, Cheol Song, H.S. Kwon, Gichan Cho
2 citations
Shoulder Injury and Treatment
1.15
article

An Optical Interferometer-based Force Sensor System for Enhancing Precision in Epidural Injection Procedure

Jintaek Im, Cheol Song, H.S. Kwon, Gichan Cho
article en
2 citations

Abstract

In minimally invasive pain management procedures, precise needle positioning is paramount for effective treatment and patient safety. Traditional techniques like the loss-of-resistance (LOR) method may be insufficient, especially in patients with narrowed epidural spaces. The use of imaging tools such as C-arms carries risks due to radiation exposure for medical professionals. A new system for detecting the epidural space based on optical interferometry is proposed to tackle this issue. Prior research has focused on force measurement systems to identify tissue puncture or rupture. Although mechanical sensors have been utilized, they add bulk and complexity to systems. Optical sensors like Fiber Bragg grating (FBG) and Fabry-Pérot interferometer (FPI) offer stable, high-resolution measurements suitable for complex biological tissues. This study aims to develop a sensor and needle system for epidural injections, incorporating quantitative metrics for validation. An optical interferometer-based force measurement sensor was integrated into a commercial epidural needle, and calibration was performed to establish a correlation between system output and actual force. The system employs a graphical user interface (GUI) to identify puncture points based on abrupt force decreases. A user study involving interventionalists assessed the system’s performance by measuring invasive depth and success rates. The user study demonstrated that the proposed sensorized system could detect the puncture with an average success rate of 72.63 %. This study represents a significant advancement toward safer and more precise epidural procedures, addressing critical clinical considerations for practical applications.

Daegu Gyeongbuk Institute of Science and Technology (KR), Asan Medical Center (KR)
Affordable and clean energy
Openalex Percentile: Top 19%
Shoulder Injury and Treatment
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.