Parameter optimization of femtosecond laser pulses for implant cavity preparation

Femtosecond laser pulses are employed in the preparation of implant cavities during dental implant surgeries in the field of digital dentistry, specifically focusing on optimizing laser pulse parameters to enhance precision and control thermal injury. In this study, <i>ex vivo</i> experiments were conducted on sheep tibiae, where thermocouple sensors monitored the temperature variations during ablation. This approach aims to optimize the laser pulse parameters and control the temperature, ensuring smoother cavity margins and better preservation of the bone microarchitecture. Scanning electron microscopy (SEM) confirmed significant improvements in the quality of the implant cavities prepared using the femtosecond laser pulses.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-12-26
DOI
https://doi.org/10.1364/boe.546367
Citations
1
Primary Topic
Ocular and Laser Science Research
Type
article
Field-Weighted Citation Impact
0.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parameter optimization of femtosecond laser pulses for implant cavity preparation

Wanqiang Chen, Wei Yi, Lei Yan, Shanshan Liang et al.
1 citations
Biomedical Optics Express
Ocular and Laser Science Research
0.54
article

Parameter optimization of femtosecond laser pulses for implant cavity preparation

Wanqiang Chen, Wei Yi, Lei Yan, Shanshan Liang, Chen Qu, Fusong Yuan, Xuesong Shi, Shuang Lin, Xiang Li
article en
1 citations

Abstract

Femtosecond laser pulses are employed in the preparation of implant cavities during dental implant surgeries in the field of digital dentistry, specifically focusing on optimizing laser pulse parameters to enhance precision and control thermal injury. In this study, <i>ex vivo</i> experiments were conducted on sheep tibiae, where thermocouple sensors monitored the temperature variations during ablation. This approach aims to optimize the laser pulse parameters and control the temperature, ensuring smoother cavity margins and better preservation of the bone microarchitecture. Scanning electron microscopy (SEM) confirmed significant improvements in the quality of the implant cavities prepared using the femtosecond laser pulses.

Biomedical Optics ExpressVol. 16(2)
King University (US), Peking University (CN), Beijing Forestry University (CN), Beijing Luhe Hospital Affiliated to Capital Medical University (CN)
National Natural Science Foundation of China, Beijing Municipal Natural Science Foundation, National Key Research and Development Program of China
Openalex Percentile: Top 28%
Ocular and Laser Science Research
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.