Comparison of Non-Invasive and Minimally Invasive Preimplantation Genetic Testing for Aneuploidy Using Samples Derived from the Same Embryo Culture

<b>Background/Objectives</b>: To assess the ploidy status of embryos via preimplantation genetic testing for aneuploidy (PGT-A), a biopsy of trophectoderm (TE) cells can be performed. However, this approach is considered invasive, and therefore the aim of this study was to identify the optimal sample type and sampling day for non-invasive or minimally invasive PGT-A (ni/miPGT-A) in terms of data quality and concordance rates with TE biopsies derived from the same embryos. <b>Methods</b>: This study was performed using 239 embryo cultures. After optimization using 96 embryos, non-invasive spent culture media (SCM) and a minimally invasive combination of blastocoel fluid and SCM (BF+SCM), along with the corresponding TE samples, were collected from 143 embryos cultured for 5 days (n = 70) or 6 days (n = 73), and all were subjected to ni/miPGT-A with whole-genome amplification followed by next-generation sequencing. <b>Results</b>: The amplification failure rate was lower for SCM samples than for BF+SCM (SCM: 0.7%, 1/143 vs. BF+SCM: 7.7%, 11/143; <i>p</i> = 0.005). The rate of ploidy concordance with TE was significantly higher for SCM samples than for BF+SCM samples (SCM: 83.7%, 118/141 vs. BF+SCM: 58%, 76/131; <i>p</i> < 0.001). Among SCM samples, concordance rates were higher for samples derived from embryos cultured for 6 days (87.5%, 63/72) than for 5 days (79.7%, 55/69). In the embryos cultured for 6 days, discordant cases included five (6.9%) SCM samples with falsely negative (euploid) results that were deemed to be mosaic according to TE and four (5.6%) samples falsely found to be aneuploid. <b>Conclusions</b>: SCM samples derived from embryos cultured for 6 days can be applied in niPGT-A with subsequent verification of aneuploid samples using TE biopsy.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-12-25
DOI
https://doi.org/10.3390/jcm14010033
Citations
4
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
4.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Non-Invasive and Minimally Invasive Preimplantation Genetic Testing for Aneuploidy Using Samples Derived from the Same Embryo Culture

Anna Strychalska, Beniamin Oskar Grabarek, Klaudia Simka-Lampa, Anna Bednarska‐Czerwińska et al.
4 citations
Journal of Clinical Medicine
Prenatal Screening and Diagnostics
4.44
article

Comparison of Non-Invasive and Minimally Invasive Preimplantation Genetic Testing for Aneuploidy Using Samples Derived from the Same Embryo Culture

Anna Strychalska, Beniamin Oskar Grabarek, Klaudia Simka-Lampa, Anna Bednarska‐Czerwińska, Nikola Zmarzły, Aneta Orczyk, W. Sierka, Joanna Smoleń‐Dzirba, Emilia Morawiec, Urszula Wróblewska, Patrycja Mermer, Anna Kokot, Natalia Jodłowiec-Lubańska, Barbara Masarczyk
article en
4 citations

Abstract

<b>Background/Objectives</b>: To assess the ploidy status of embryos via preimplantation genetic testing for aneuploidy (PGT-A), a biopsy of trophectoderm (TE) cells can be performed. However, this approach is considered invasive, and therefore the aim of this study was to identify the optimal sample type and sampling day for non-invasive or minimally invasive PGT-A (ni/miPGT-A) in terms of data quality and concordance rates with TE biopsies derived from the same embryos. <b>Methods</b>: This study was performed using 239 embryo cultures. After optimization using 96 embryos, non-invasive spent culture media (SCM) and a minimally invasive combination of blastocoel fluid and SCM (BF+SCM), along with the corresponding TE samples, were collected from 143 embryos cultured for 5 days (n = 70) or 6 days (n = 73), and all were subjected to ni/miPGT-A with whole-genome amplification followed by next-generation sequencing. <b>Results</b>: The amplification failure rate was lower for SCM samples than for BF+SCM (SCM: 0.7%, 1/143 vs. BF+SCM: 7.7%, 11/143; <i>p</i> = 0.005). The rate of ploidy concordance with TE was significantly higher for SCM samples than for BF+SCM samples (SCM: 83.7%, 118/141 vs. BF+SCM: 58%, 76/131; <i>p</i> < 0.001). Among SCM samples, concordance rates were higher for samples derived from embryos cultured for 6 days (87.5%, 63/72) than for 5 days (79.7%, 55/69). In the embryos cultured for 6 days, discordant cases included five (6.9%) SCM samples with falsely negative (euploid) results that were deemed to be mosaic according to TE and four (5.6%) samples falsely found to be aneuploid. <b>Conclusions</b>: SCM samples derived from embryos cultured for 6 days can be applied in niPGT-A with subsequent verification of aneuploid samples using TE biopsy.

Journal of Clinical MedicineVol. 14(1)
WSB University (PL)
Openalex Percentile: Top 6%
Prenatal Screening and Diagnostics
4.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.