Gamma-Ray Spectroscopy Using an Unfolding Method with Response Functions Including the Energy Dependencies of Scintillation Efficiency for the NaI(Tl) Scintillator

Background: Measuring the energy spectrum of γ rays to assess the exposure dose and identifying the leaked radioisotopes at the accident site and the surrounding environment is necessary in the case of an accident involving the leakage of radioactive material at a nuclear power plant or a radiation-related facility. High-purity germanium semiconductor detectors are utilized for γ-ray spectrometry due to their high energy resolution, but they exhibit a high initial and operational cost due to the need for a cooling mechanism.Materials and Methods: We improved the unfolding method for scintillators with a refined response function that involves the energy dependence of scintillation efficiency for secondary electrons produced by incident γ-ray interaction. Monte Carlo simulation code EGS5 with a mesh width of 5 keV in the energy range of 0–3 MeV was used to calculate response functions, assuming γ rays irradiated parallel to the detector sides. The unfolding algorithm involves an iterative approximation method, which is independent of initial guesses.Results and Discussion: The measurement accuracy of the γ-ray fluence rate was almost constant at <10% at ≥0.3 MeV caused by repeated measurements using 137Cs, 133Ba, 88Y, and 60Co radiation sources. Additionally, we confirmed linearity concerning the γ-ray intensity by changing the distance from the source to the detector.Conclusion: We verified that the unfolding method separated peaks for each γ-ray energy, although the difference in γ-ray energies was several tens of keV. Moreover, the accuracy of the unfolding method was almost constant and had linearity concerning γ-ray intensity.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Protection and Research
Published
2024-12-25
DOI
https://doi.org/10.14407/jrpr.2023.00416
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gamma-Ray Spectroscopy Using an Unfolding Method with Response Functions Including the Energy Dependencies of Scintillation Efficiency for the NaI(Tl) Scintillator

Hiroshi Nishizawa, M. Hayashi, Tetsushi Azuma, Masakazu Nakanishi et al.
Journal of Radiation Protection and Research
Radiation Detection and Scintillator Technologies
article

Gamma-Ray Spectroscopy Using an Unfolding Method with Response Functions Including the Energy Dependencies of Scintillation Efficiency for the NaI(Tl) Scintillator

Hiroshi Nishizawa, M. Hayashi, Tetsushi Azuma, Masakazu Nakanishi, Taisuke Makita, M. Sasano
article en

Abstract

Background: Measuring the energy spectrum of γ rays to assess the exposure dose and identifying the leaked radioisotopes at the accident site and the surrounding environment is necessary in the case of an accident involving the leakage of radioactive material at a nuclear power plant or a radiation-related facility. High-purity germanium semiconductor detectors are utilized for γ-ray spectrometry due to their high energy resolution, but they exhibit a high initial and operational cost due to the need for a cooling mechanism.Materials and Methods: We improved the unfolding method for scintillators with a refined response function that involves the energy dependence of scintillation efficiency for secondary electrons produced by incident γ-ray interaction. Monte Carlo simulation code EGS5 with a mesh width of 5 keV in the energy range of 0–3 MeV was used to calculate response functions, assuming γ rays irradiated parallel to the detector sides. The unfolding algorithm involves an iterative approximation method, which is independent of initial guesses.Results and Discussion: The measurement accuracy of the γ-ray fluence rate was almost constant at <10% at ≥0.3 MeV caused by repeated measurements using 137Cs, 133Ba, 88Y, and 60Co radiation sources. Additionally, we confirmed linearity concerning the γ-ray intensity by changing the distance from the source to the detector.Conclusion: We verified that the unfolding method separated peaks for each γ-ray energy, although the difference in γ-ray energies was several tens of keV. Moreover, the accuracy of the unfolding method was almost constant and had linearity concerning γ-ray intensity.

Journal of Radiation Protection and ResearchVol. 50(s1)
Fukui University of Technology (JP), Mitsubishi Electric (Japan) (JP)
Affordable and clean energy
Openalex Percentile: Top 66%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.