Experimental Evaluation of Maximum-Likelihood-Based Data Preconditioning for DE-SPECT: A Clinical SPECT System Constructed With CZT Imaging Detectors

This study introduces a novel maximum-likelihood-based data preconditioning method for a 3-D position sensitive cadmium zinc telluride (CZT) detector used in the dynamic extremity-single photon emission computed tomography imaging system, an organ-dedicated Single-Photon Emission computed tomography system optimized for imaging peripheral vascular diseases in lower extremities. The 3-D CZT detectors offer subpixel resolution of ~0.5 mm FWHM in <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi> <mml:mo>-</mml:mo> <mml:mi>Y</mml:mi> <mml:mo>-</mml:mo> <mml:mi>Z</mml:mi></mml:math> directions and an ultrahigh energy resolution of 3 keV at 200 keV, 4.5 keV at 450 keV, and 5.4 keV at 511 keV. Given the intrinsic challenges posed by pixel boundary issues, spatial distortions, and nonuniformity inherent in large-volume, high-resolution CZT detectors, we proposed a Maximum-Likelihood-based preconditioning technique to reconstruct the projection, which effectively mitigates the pixel boundary issue and deconvolves the distortions and nonuniformity in detector responses. To facilitate the preconditioning step, we used sheet-beam scanning to measure the distortion map of the CZT detectors. We have evaluated our data preconditioning technique through extensive experimental evaluations, including Tc-99m sheet-beam scanning and image reconstruction of an image quality phantom. These results not only demonstrated the efficacy of the technique in reducing the impact of pixel boundary issues and correcting for spatial distortions. The proposed data preconditioning technique could potentially be applied across various types of imaging sensors.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2024-12-25
DOI
https://doi.org/10.1109/trpms.2024.3520668
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Evaluation of Maximum-Likelihood-Based Data Preconditioning for DE-SPECT: A Clinical SPECT System Constructed With CZT Imaging Detectors

Elena Zannoni, Ling-Jian Meng, Y. J. Jin
IEEE Transactions on Radiation and Plasma Medical Sciences
Advanced X-ray and CT Imaging
article

Experimental Evaluation of Maximum-Likelihood-Based Data Preconditioning for DE-SPECT: A Clinical SPECT System Constructed With CZT Imaging Detectors

Elena Zannoni, Ling-Jian Meng, Y. J. Jin
article en

Abstract

This study introduces a novel maximum-likelihood-based data preconditioning method for a 3-D position sensitive cadmium zinc telluride (CZT) detector used in the dynamic extremity-single photon emission computed tomography imaging system, an organ-dedicated Single-Photon Emission computed tomography system optimized for imaging peripheral vascular diseases in lower extremities. The 3-D CZT detectors offer subpixel resolution of ~0.5 mm FWHM in <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi> <mml:mo>-</mml:mo> <mml:mi>Y</mml:mi> <mml:mo>-</mml:mo> <mml:mi>Z</mml:mi></mml:math> directions and an ultrahigh energy resolution of 3 keV at 200 keV, 4.5 keV at 450 keV, and 5.4 keV at 511 keV. Given the intrinsic challenges posed by pixel boundary issues, spatial distortions, and nonuniformity inherent in large-volume, high-resolution CZT detectors, we proposed a Maximum-Likelihood-based preconditioning technique to reconstruct the projection, which effectively mitigates the pixel boundary issue and deconvolves the distortions and nonuniformity in detector responses. To facilitate the preconditioning step, we used sheet-beam scanning to measure the distortion map of the CZT detectors. We have evaluated our data preconditioning technique through extensive experimental evaluations, including Tc-99m sheet-beam scanning and image reconstruction of an image quality phantom. These results not only demonstrated the efficacy of the technique in reducing the impact of pixel boundary issues and correcting for spatial distortions. The proposed data preconditioning technique could potentially be applied across various types of imaging sensors.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(5)
University of Illinois Urbana-Champaign (US)
National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 77%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.